Mcdonnell Douglas MD 83
Service difficulty reports · 3,415
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD83' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD83' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR WX0A071845Cusp Web · corrodedCABIN CUSP WEB AT STATION 368 - 389 RBL 56 HAS CORROSION IN MULTIPLES AREAS. REMOVED DAMAGE FROM CUSP WEB & FABRICATED, DOUBLER, FILLERS, LOCATED, DRILLED & INSTALLED IAW SRM 53-05 FIG 131-21.SDR WX0A071843Battery · dischargedEMERGENCY LIGHTS AT ROW 24 INOPERATIVE. REPLACED BATTERY POWER SUPPLY IAW AMM 33-53-00. SYS OPERATIONS NORMAL.SDR WX0A071844Tab · nickedLEFT ELEVATOR ANTI-FLOAT TAB HAS SMALL NICK ON OTBD CORNER. REPAIRED NICK ON LT ELEVATOR ANTI-FLOAT TAB IAW SRM 51-70-2 PARA 13 PG 64. HOT BOND DOUBLER REPAIR.SDR WX0A071842Battery Pack · dischargedFORWARD CABIN UPPER EMERGENCY FLASHLIGHT INOPERATIVE. R & R FWD CABIN UPPER EMERGENCY FLASHLIGHT BATTERY PACK IAW AMM 25-60-00. OPERATIONS CHECKED GOOD.SDR WX0A071841Battery · dischargedAFT CABIN FLASHLIGHT NOT FLASHING. REPLACED AFT CABIN EMERGENCY FLASHLIGHT BATTERY & OPERATIONS CHECKED GOOD.SDR YYFA20140207001Interphone · inoperativeL2 INTERPHONE & PA INOPERATIVE.SDR WX0A071840Doubler · crackedDURING TAIL CONE RELEASE CHECK NOTED CRACK ON REPAIR DOUBLER AT CANTED FRAME 1485, RT LONGERON 3 - 4. REMOVED CRACKED REPAIR AT CANTED FRAME 1485, RT LONGERON 3 - 4 & INSTALLED NEW DOUBLER IAW SRM 53-01 FIG 2 SHEET 3 PG12, 53-14-4 FIG 3 & 51-10-4.SDR WX0A071839Structure · crackedAFT CARGO DOOR, AFT SIDE, HAS MULTIPLE CRACKS JUST BELOW AFT TORQUE TUBE. CUTOUT DAMAGED AREA, FABRICATED, LOCATED, DRILLED, REPAIRED PARTS & INSTALLED PERMANENT REPAIR IAW SRM 52-05 PAR 26 FIG 26B.SDR WX0A071838Tee Fitting · crackedTEE ON CABIN FLOOR FRAME LBL 22 AT FS 905 IS CRACKED. R & R DAMAGED TEE ON CABIN FLOOR FS 905 & LBL 22 IAW SRM 51-01 PARAGRAPH 2 D.SDR WX0A071837Skin · dentedFORWARD CARGO DOOR HAS MULTIPLE DENTS ALONG LOWER EDGE. REPAIRED FWD CARGO DOOR LOWER EDGE IAW SRM 52-05 FIG 67.SDR YYFA20140206001Unknown · malfunctionedON TAKEOFF FIRST OFFICER REPORTED PULLING TO THE LT WITH A NOISE COMING FROM NOSE GEAR, TAKE OFF ABORTED.SDR WX0A071836Skin · dentedFORWARD CARGO DOOR SKIN IS DENTED AT FWD EDGE APPROXIMATELY 14 INCHES FROM THE BOTTOM. CUTOUT DAMAGED AREA, FABRICATED REPAIR DOUBLER, FILLER & INSTALLED REPAIR PARTS IAW SRM 52-05 FIG 67.SDR WX0A071835Former · crackedOUTER SKIN TO FUSELAGE CLIP AT STATION 769 JUST BELOW LONGERON 10 APPEARS TO BE CRACKED IN UPPER CORNER. REMOVED DAMAGED SECTION, FABRICATED REPAIR PARTS & INSTALLED REPAIR PARTS IAW SRM 53-03 FIG 44.SDR YYFA20140203001Warning Light · illuminatedFLOW LIGHT CAME BACK ON DURING CRUISE & CLIMB 250. PERFORMED QRH PROCEDURE. WE WERE NOT ABLE TO FIX THE PROBLEM, RETURNED TO DEPARTURE AIRPORT.SDR WX0A071834Power Supply · defectiveEMERGENCY LIGHTS FLASHED ON & OFF DURING CRUISE. R & R POWER SUPPLY AT STATION 223 IAW AMM CH 33-53-00, OPERATIONS CHECKED GOOD.SDR WX0A071833Battery Pack · dischargedEMERGENCY LIGHTS AT AFT FLIGHT ATTENDANT’S STATION INOPERATIVE. R & R AFT FLIGHT ATTENDANT`S STATION BATTERY PACK IAW AMM 33-53-00. OPERATIONS CHECKED NORMAL AT THIS TIME.SDR YYFA201401310001Unknown · defectivePRIOR TAKING THE RUNWAY FOR DEPARTURE, A LARGE GRINDING MECHANICAL NOISE FROM NOSE WHEEL HEARD & NOTICED WHEN LINED UP IN THE RUNWAY. NOSE WHEEL WAS CONTROLLABLE POORLY.SDR WX0A071832Battery · dischargedLEFT & RT AFT OVERWING EXIT DOORS UPPER EXIT SIGNS ARE INOPERATIVE. R & R BATTERY'S FOR LT & RT AFT OVERWING DOORS EXIT SIGNS IAW 33-53-01, OPERATIONS GOOD.SDR WX0A071830Battery · dischargedAFT ATTENDANT`S JUMP SEAT OVERHEAD EMERGENCY LIGHTS INOPERATIVE. R & R EA BATTERIES & OPERATIONS CHECKED GOOD IAW AMM 33-53-00.SDR WX0A071829Light · inoperativeEMERGENCY EXIT LIGHTS AT ROW 14DEF - 18DEF INOPERATIVE.SDR WX0A071904Jackscrew · out of limitsJACKSCREW FAILED END PLAY LIMITS & REQUIRES REPLACEMENT. R & R LONGITUDINAL TRIM ACTUATION MECHANISM JACKSCREW IAW 27-40-01. SYS OPERATIONS CHECKED GOOD. COMPLIED WITH JACK SCREW WEAR INSPECTION ON WO 216189.SDR MJYA20140217001Stringer · corrodedSTRINGER 30 CORRODED BETWEEN STATIONS 275 & 294.SDR YYFA20140125001Battery Pack · dischargedEMERGENCY LIGHTS AT STATION 294 THRU 500R LIGHT PACK INOPERATIVE. R &R EMERGENCY BATTERY PACK IAW MM 33-53-00, OPERATIONS CHECKED NORMAL.SDR YYFA20140124001Smoke Detector · activatedMID CARGO SMOKE DETECTOR CAME ON IN FLIGHT.SDR WX0A071827Battery Pack · dischargedAFT LOWER EXIT EMERGENCY SIGN OVERWING LIGHTS ARE INOPERATIVE. REPLACED EMERGENCY PACK IAW AMM 33-53-01. SYS OPERATIONS NORMAL.SDR WX0A071825Static Inverter · faultyEMERGENCY POWER TEST FAILED. CAPTAIN`S PFD, ND, AIRSPEED & ALTIMETER REMAIN OFF. FIRST OFFICER`S FUNCTIONS ON EMERGENCY POWER. R & R STATIC INVERTER IAW AMM 24-23-01, OPERATIONS CHECKED GOOD.SDR YYFA201421002Pa System · faultyFRONT PA IS TOO LOW TO HEAR CAPTAIN'S OR FLIGHT ATTENDANT'S.SDR YYFA20140121001Handset · inoperativeAFT ATTENDANT HANDSET INOPERATIVE.SDR WX0A071824Power Supply · inoperativeOVERWING EMERGENCY LIGHT INOPERATIVE. R & R POWER SUPPLY & OPERATIONS CHECKED NORMAL IAW AMM 33-53-00.SDR WX0A071823Battery · dischargedAFT FLIGHT ATTENDANT`S POSITION, ONE EMERGENCY FLASHLIGHT NOT FLASHING. REPLACED BATTERY IN FLASHLIGHT IAW AMM 25-60-00.SDR WX0A071822Battery · discharged21-24 EMERGENCY LIGHTS INOPERATIVE. R & R EMERGENCY BATTERIES & OPERATIONS CHECKED NORMAL IAW AMM 33-55-01.SDR YYFA201401200001Handset · inoperativeFORWARD ATTENDANCE PA HAND SET INOPERATIVE.SDR WX0A071826Controller · malfunctionedCLIMBING THROUGH FL 220 PRESSURIZATION FAILED CABIN ALT CLIMBING RAPIDLY, NO FLOW HIGH. FOLLOWED QRH LED TO DEPLOYING PAX O2 MASKS. R & R NR 1 & NR 2 PRESS CONTROLLERS IAW MM 21-32-03. R & R ONE EACH PRESS CONTROLLER LINE ON NR 1 PRESS CONTROLLER IAW MM 21-3SDR WX0A071821Control Valve · leakingLAVATORY SMOKE ALARM ON DEPARTURE, NO VISIBLE SMOKE OR FIRE BUT ODD SMELL IN AFT RT LAVATORY. FOUND A LEAK AT THE LT THRUST REVERSER CONTROL VLV & APU OIL PUMP SUCTION LINE. TIGHTENED ALL FITTINGS, LEAK CHECK GOOD. PERFORMED PACK BURN OUT & CHANGED THE COALSDR WX0A071820Battery · dischargedLEFT & RT AFT OVERWING EXIT DOOR UPPER EXIT SIGNS INOPERATIVE. R & R BATTERIES FOR OVERWING EXIT DOOR SIGNS IAW AMM 35-53-00.SDR WX0A071819Battery · dischargedTAIL COMPARTMENT OVERHEAD EMERGENCY LIGHTS INOPERATIVE. R & R BATTERIES IN BATTERY PACK B5-28 IAW AMM-33-53-00. OPERATIONS CHECKED NORMAL.SDR WX0A071818Battery · dischargedCOCKPIT EMERGENCY LIGHTS INOPERATIVE ON OVERHEAD PANEL DURING COCKPIT PREFLIGHT. R & R COCKPIT EMERGENCY LIGHTS BATTERIES IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.SDR YYFA20140112001Light · inoperativeNO GREEN LIGHT FOR LT MLG AFTER GEAR EXTENSION, RELAMPED.SDR 7AHR201410243Lock · damagedDURING A C CHECK THE FLIGHT DECK DEAD BOLT FAILED FUNCTIONAL TEST. DISCOVERED THE DOOR DEAD BOLT HANDLE DAMAGED. R & R DEAD BOLT PN AA87113 IAW DC-9 MM 52-52-1-2 E1-E-7 PAGE 4.SDR 7AHR201410258Channel · corrodedDURING A C CHECK INSPECTION CORROSION WAS NOTED ON STRUCTURE ATTACHED TO THE BOTTOM OF THE AFT LAV PAN. R & R SECTION OF HAT CHANNEL IAW MD-80 SRM 51-30-5 PGS 1, 2 & 6 & 51-30-2 PGS 1-3.SDR 7AHR201410236Door Frame · damagedDURING A C CHECK THE AFT BULKHEAD DOOR JAMB, WAS NOTED WITH DAMAGE AT THE UPPER & LOWER DOOR LATCH POINTS. A 5 DOUBLER WAS INSTALLED IAW MD-80 SRM 53-05, FIG 69.SDR YYFA20140110001Proximity Switch · dirtyRETURNED TO LAND AT KPGD DUE TO AVIONICS COMPARTMENT DOOR LT. FOUND PROX SW DIRTY CLEANED PROX SW, OPERATIONS CHECKED NORMAL IAW 52-44-01.SDR WX0A071817Power Supply · inoperativeTWO EACH EXTERIOR EMERGENCY LIGHTS INOPERATIVE. R & R POWER SUPPLY, OPERATIONS CHECKED NORMAL IAW AMM 33-53-00.SDR YYFA20130109003Radar · failedWEATHER RADAR FAILED EN ROUTE TO KDSM AIR RETURN.SDR YYFA20140109002Unknown · malfunctionedRC PA SYS GETTING FEEDBACK AFTER ENG START.SDR YYFA20140109001Dfgs · failedART FIRED AFTER DFGS FAILED. REPLACED DFGS, OPERATIONS CHECKED NORMAL.SDR WX0A071816Battery · dischargedEMERGENCY LIGHTS INOPERATIVE BETWEEN ROWS 33 & 34. R & R BATTERIES IN EMERGENCY LIGHTS BATTERY PACK B5-107. OPERATIONS CHECKED GOOD IAW AMM 33-53-00.SDR WX0A071815Battery · dischargedEMERGENCY LIGHTS INOPERATIVE BETWEEN ROWS 22 & 24. R & R BATTERIES IN EMERGENCY LIGHTS BATTERY PACK B5-104. OPERATIONS CHECKED GOOD IAW AMM 33-53-00.SDR YYFA20140107002Smoke Detector · faultyMID CARGO SMOKE DETECTOR LOOP A FAIL LIGHT ON.SDR YYFA20140107001Light · inoperativeEMERGENCY EXIT LIGHT AT L1 DOOR INOPERATIVE.
Back to Mcdonnell Douglas MD 83