Mcdonnell Douglas MD 83
Service difficulty reports · 3,415
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD83' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD83' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR YYFA20131201002Interphone · faultyINTERPHONE IN FLT DECK NOT ABLE TO HEAR FLIGHT ATTENDANT SPEAKING.SDR YYFA20131201001Light · inoperativeEMERGENCY LIGHTS INOPERATIVE IN THE TAIL CONE.SDR WX0A071764Battery · dischargedIAW MEL 25-09 DMI 5478 FWD FLIGHT ATTENDANT`S EMERGENCY FLASHLIGHT INOPERATIVE. R & R FWD FLIGHT ATTENDANT`S EMERGENCY FLASHLIGHT BATTERY IAW AMM 25-60-00, OPERATIONS CHECKED NORMAL. THIS CLEARS DMI 5478 PLACARDS REMOVED.SDR YYFA20131126001Handset · faultyHANDSET WILL NOT TURN OFF TO TALK MODE, BOTH L2 & RC LOW VOLUME WHEN TALKING ON INTERPHONE.SDR WX0A071761Battery Pack · dischargedL2 DOOR EMERGENCY EXIT SIGN DOES NOT ILLUMINATE. R & R THE EMERGENCY POWER SUPPLY BATTERY PACK IAW AMM 33-53-00, OPERATIONS CHECKED GOOD.SDR YYFA20131125001Switch · brokenCOCKPIT PA PHONE PTT SWITCH ON HANDSET BROKEN & INOPERATIVE.SDR WX0A071763Unknown · odorPASSENGERS IN AFT ACFT COMPLAINED OF FUEL SMELL. INSPECTED APU FUEL SYS FOR LEAKS IAW AMM 49-30-01, NO LEAKS NOTED. PERFORMED AC PACK BURN OUT IAW TC 0592101. NO ODOR NOTED AT THIS TIME ACFT OK FOR CONTINUED SERVICE.SDR WX0A071762Socket · meltedFLIGHT ATTENDANT`S & PAX REPORTED FUMES IN AFT CABIN MAINLY LT SIDE. PERFORMED QRH 26.2 PULLED RECIRC BREAKERS WITH NO HELP. SECURING RT PACK CAUSED FUMES TO DISAPPEAR. FUMES WERE DESCRIBED AS MELTING ELECTRICAL. FOUND AIR LEAKING FROM RT ACM. RT PACKED DESDR 7AHR20131129003Torque Tube · wornUPON REMOVAL OF RUDDER ASSEMBLY, THE TORQUE TUBE ASSEMBLY WAS FOUND TO HAVE PITTING CORROSION & WEAR DAMAGE BEYOND ALLOWABLE LIMITS.SDR 7AHR20131129002Support Fitting · corrodedLEFT HAND OTBD TE FLAP SUPPORT FITTING ASSEMBLY & MOUNTING STUDS HAD PITTING CORROSION DAMAGE AT C CHECK INSPECTION BEYOND ALLOWABLE LIMITS.SDR 7AHR20131129001Gauge · brokenEVACUATION SLIDE AT L1, MAIN ENTRY DOOR HAD BROKEN PRESS GAUGE AT TIME OF C CHECK INSPECTION.SDR YYFA20131120001Speaker · brokenL2 JUMP SEAT SPEAKER BROKEN.SDR 7AHR20131129004Door Frame · crackedDOOR FRAME CRACKED AT AFT DOOR LATCH LOCATION ON LOWER, MID CARGO COMPARTMENT DOOR BEHIND EXISTING REPAIR.SDR WX0A071759Battery · dischargedCOCKPIT & GALLEY EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERIES IAW MM 33-53-00, OPERATIONS CHECKED GOOD.SDR IU6R2013FA0000594Housing · crackedPIN HOLE ON SIDE OF THE PRESSURE PORT OF THRUST REVERSER CONTROL VALVE.SDR WX0A201309260004Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MX REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYS WOULD NOT TEST. MX R & R BATTERY PACK AND OPS CHECKED IAW AMM 33-50-00, SYS OPS CHECKED NORMAL. ACFT RETURNED TO SERVICE.SDR AALA20130820007Apu · failedDFW CREW REPORTED AUXILIARY POWER UNIT FAILED WITH AC CROSS TIE ON PLACARD. EMERGENCY DECLARED FLIGHT RETURNED DFW LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED AUXILIARY POWER UNIT. SYSTEM GROUND CHECKED NORMAL OPERATION CLOSEDSDR AALA20130621006Doubler · crackedINNER FILLER SKIN DOUBLER CRACKED AT BS 1463 & LONGERON 3 LT. STOP DRILLED CRACK & DOUBLER INSTALLED IAW SRM 53-01-00 FIGURE 2 SHEET 3 & EA.SDR AALA20130621005Skin · damagedFUSELAGE SKIN DAMAGED BS 1463 BELOW SKATE ANGLE LT HAND SIDE. CUT OUT DAMAGED AREA & INSTALLED DOUBLER IAW SRM 53-01-00 FIGURE 2 SHEET 3 & SUPPORTING EA.SDR AALA20130621004Doubler · damagedSTRAP DOUBLER BLENDED OUT OF LIMITS. FABRICATED STRAP DOUBLER IAW AARD 51-00-00-1 & EA.SDR AALA20130618021Battery Pack · dischargedROWS 12 - 23 EMERGENCY LIGHTS ON LEFT SIDE INOPERATIVE. REPLACED BATTERY PACK B5-101. OPERATIONS CHECKED NORMAL.SDR AALA20130620004Cusp Web · corrodedRIGHT HAND CUSP HAS HOLE AT BS 876. REMOVED CORROSION & INSTALLED DOUBLER IAW AARD 53-20-00-16.SDR AALA20130620003Cusp Web · corrodedCORROSION ON BOTTOM OF RIGHT HAND CUSP AT BS 487. REMOVED CORROSION AND INSTALLED DOUBLER IAW AARD 53-20-00-16.SDR AALA20130620005Web · crackedWEB CRACKED AT BS 207 & LONGERON 15 LT. REMOVED DAMAGE & INSTALLED DOUBLER IAW 53-10-00-11.SDR AALA20130618009Membrane · damagedDAMAGE ON SUB-FLOOR AT BS 200 & 12 INCHES LT OF CENTERLINE. INSTALLED REPAIR DOUBLER IAW AARD 53-20-00-16.SDR WX0A071602Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A071596Frame · corrodedAFT CARGO FRAME AT STATION 1309 CORRODED BETWEEN LONGERON L24R TO 24L. REPAIRED FRAME.SDR WX0A071591Frame · crackedLEFT FUSELAGE AT STATION 1474 CANT FRAME CRACKED. REPAIRED LEFT FUSELAGE AT STATION 1474 CANT FRAME.SDR WX0A071590Frame · crackedAFT FUSELAGE CANTED FRAME AT STATION 1463 UPPER LEFT SIDE WEB CRACKED. REPAIRED CANTED FRAME WEB.SDR WX0A071589Skin · dentedLEFT ELEVATOR CONTROL TAB HAS A DENT ON LOWER I/B SURFACE. REPAIRED DENT.SDR WX0A071587Cap · brokenRIGHT ELEVATOR NR 5 LEADING EDGE CAP IS BROKEN AT I/B BOTTOM CORNER. FABRICATED REPAIR PARTS AND INSTALLED.SDR WX0A2013051371579Thrust Reverser · dentedNR 2 ENGINE T/R LOWER CLAM SHELL DENT AT 3RD RIB. LENGTH 5.2 WIDTH 2.8 DEPTH .033 D/X RATIO OF 84.8 FOUND TO BE WITHIN LIMITS.SDR WX0A071578Skin · dentedUPPER LEFT FUSELAGE SKIN DENT STATION 218 LONGERON 3L. LENGTH 1.5 DEPTH .018 D/X RATIO OF 83.3. FOUND TO BE WITHIN LIMITS.SDR WX0A2013051371575Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A2013051371573Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A2013051371572Slide · unserviceableSLIDE PACK ON TAIL CONE INDICATES IN RED. REMOVED AND REPLACED TAIL CONE EVAC SLIDE IAW TASK CARD R0902503 REF 25-62-01.SDR WX0A071568Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A2013042271564Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A2013042271565Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A2013041771562Eyebolt · detachedAFTER TAKEOFF ELEVATOR HAD VIBRATION AND ABNORMALLY DIFFICULT TO MOVE. TAKEOFF TRIM 8.0 AFTER TAKEOFF TRIMMED TO 0. LANDED WITH 3.0. FOUND RT ELEVATOR EYEBOLT ON ACTUATOR DETACHED FROM ELEVATOR. INSTALLED EYEBOLT PER AMM 27-30-08. ACP SYSTEM TEST. ALL NORMSDR WX0A2013041571560Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST AT ROW 25. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPSDR WX0A2013041571559Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A2013041071553Skin · puncturedLEFT WING TRAILING EDGE I/B FLAP I/B VANE LOWER SURFACE IS PUNCTURED. REMOVED, REPAIRED AND RE-INSTALLED LEFT I/B FLAP VANE.SDR WX0A2013041071555Unknown · odorSTRONG SMELL OF MELTING PLASTIC ON TAXI OUT. SEEMED TO DISSIPATE WHEN PACKS TURNED OFF. INSPECTED CABIN AND RAN APU AND BOTH ENGINES WITH NO SMELL NOTED.SDR WX0A2013041071552Skin · damagedTEMPORARY SKIN REPAIR AT STATION 1198 TO 1211 LONGERON 28R TO 30. REQUIRES A PERMANENT REPAIR. ACCOMPLISHED A PERMANENT SKIN REPAIR AT STATION 1198 TO 122 AND LONGERON 28R TO 30. INTERNAL FILLER MEASURES 8' X 9" AND EXTERNAL DOUBLER MEASURES APPROXIMATELY 2SDR WX0A2013041071551Beam · corrodedAFT CARGO DOOR JAMB BEAM CORRODED AT STATION 1155 TO 1212. FOUND WHILE WORKING DROP-IN NON-ROUTINE M301 ITEM. CUT OUT DAMAGED AREA OF BEAM. HFEC INSPECTED WITH NO CRACKS NOTED. FABRICATED REPAIR PARTS. LOCATED, DRILLED AND INSTALLED.SDR WX0A2013041571558Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A2013040171547Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A2013040171548Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A2013032171543Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
Back to Mcdonnell Douglas MD 83