Mcdonnell Douglas MD-88
Service difficulty reports · 21,991
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD88' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD88' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2016053004218Intercostal · crackedCRACKED INTERCOSTAL X=0 BETWEEN BS 1287 AND 1309. NEW INTERCOSTAL WAS INSTALLED IAW SRM 51-30-2 AND 51-30-1.SDR DALA2016053004190Connector · corrodedCREW REPORTED MINIMAL BRAKING AVAILABLE DURING LANDING WITH MANUAL APPLICATION. A POST FLIGHT INVESTIGATION REVEALED A BRAKE TEMP DIFFERENCE BETWEEN THE OTBD, HOT AND INBD, COOL. MAINTENANCE FOUND CONNECTORS ON NR 3 WHEEL TRANSDUCER AND NR 2 BRAKE SERVO BADLSDR DALA2016053004219Door Frame · corrodedFWD CARGO DOOR FRAME UNDER ENTRY SCUFF PLATE CORRODED. DOOR FRAME OF SRM LIMITS. REMOVED AND REINSTALLED NEW LOWER PAN. REPAIRED IAW SRM 53-05, FIG 44A.SDR DALA2016052704215Switch · inoperativeALL EMERGENCY LIGHTS INOPERATIVE. R & R FWD ATTEND SWITCH S1-387. OPS CK GOOD, REF WDM 33-51-11.SDR DALA2016052704214Battery Pack · inoperativeEMERGENCY EXIT LIGHT INOPERATIVE ON BOTH AFT OVERWING EXIT DOORS. R & R THE BATTERY PACK IAW SSM 33-51-00, TESTED OK.SDR DALA2016052704188Start Valve · malfunctionedFLT 1515 RETURNED TO DEPARTURE DUE TO RT ENGINE START VALVE SHOWING OPEN AND RT ENGINE OIL TEMP RISING. R & R START VALVE IAW AMM.SDR DALA2016052704187Duct · blownRETURNED TO DEPARTURE DUE TO RT ENGINE FIRE WARNING DURING CLIMB. ENGINE WAS NOT SHUTDOWN. MAINTENANCE FOUND REAR RT ANTI-ICE DUCT BLOWN. ALSO FOUND UPPER COWL DAMAGED. REPLACED RT REAR ANTI-ICE TUBE. UPPER COWL REPLACED ON LP 8019864. LEAK/ENGINE RUNS NSDR DALA2016062204835Tab · dentedINITIAL, SEVERAL DENTS ON ANTI-FLOAT TAB ON LT ELEVATOR, LT ELEVATOR ANTI-FLOAT TAB WAS REPLACED AND ITS INSTALLATION WAS ACCOMPLISHED UNDER JOB 001-0235, CARD 2730-4334.SDR DALA2016052504224Apu · smokePERFORMED ATB DUE TO REPORTED SMOKE IN CABIN ON CLIMB OUT. AN EMERGENCY WAS DECLARED. MAINTENANCE REPLACED THE APU AND PERFORMED PACK SYSTEM INSPECTION/CLEANING. A VERIFICATION FLIGHT WAS ACCOMPLISHED AND THE ACFT WAS RETURNED TO SERVICE.SDR DALA2016052604154Brake Sys · malfunctionedON TOUCHDOWN, CREW NOTED DEGRADED BRAKING ACTION WITH NORMAL BRAKE APPLICATION. FULL BRAKE PEDAL APPLICATION RESULTED IN PARTIAL BRAKING FORCE ACCORDING TO THE FLIGHT CREW. OBSERVED BRAKE TEMPS WERE NOT BALANCED BUT NO ASSOCIATED WARNINGS ON THE EOAP . MAINSDR DALA2016052604152Attach Fitting · brokenDUCT JOINT LOWER ATTACH TAB IS BROKEN, AFT OF LT GROUND BLOWER. WELDED TAB IAW ER/A 494638-14MA, REV B.SDR DALA2016052404136Slide · inoperativeMAIN CABIN DOOR WAS OPENED WITHOUT SLIDE BEING DISARMED. SLIDE DID NOT DEPLOY, BUT IS OUT OF THE DOOR. RE-INSTALLED 1L SLIDE IAW AMM 25-62. CHECK NORMAL. NO FURTHER DISCREPANCIES NOTED. AC OK FOR SERVICE.SDR DALA2016052404134Battery Pack · dischargedAFT CEILING LIGHTS, EMERGENCY, INOPERATIVE. CHANGED BATTERY'S AD2013-1A, 2 EACH. OPS CHECK GOOD.SDR DALA2016061504697Tab · dentedSEVERAL DENTS ON CONTROL TAB ON LT ELEVATOR. THE LT ELEVATOR TAB WAS REPLACED AND ITS INSTALLATION IS ACCOMPLISHED UNDER CARD 2730-4334.SDR DALA2016060704410Tab · dentedSEVERAL DENTS ON RT ELEVATOR GEARED TAB. THE RT ELEVATOR GEARED TAB WAS REPLACED AND IT INSTALLATION ON THE ACFT IS ACCOMPLISHED UNDER CARD 001--0239:2730-4832.SDR DALA2016060704409Tab · dentedSEVERAL DENTS ON RT ELEVATOR ANTI-FLOAT TAB. RT ELEVATOR ANTI-FLOAT TAB WAS REPLACED AND ITS INSTALLATION IS ACCOMPLISHED UNDER CARD 001-0239:2730-4832.SDR DALA2016060704408Tab · dentedDENTS ON GEARED TAB ON LT ELEVATOR. THE LT ELEVATOR GEARED TAB WAS REPLACED AND ITS INSTALLATION IS ACCOMPLISHED UNDER CARD 001-0235:2730-4334.SDR DALA2016052304118Switch · burnedACFT PERFORMED AN AIR TURN BACK TO DEPARTURE AFTER DETECTING AN ACRID, BURNING ELECTRICAL ODOR IN THE COCKPIT. NO VISIBLE SMOKE IN COCKPIT, BUT ODOR WAS STILL PRESENT AFTER RETURNING TO THE GATE. MAINTENANCE FOUND THE LEFT WING LANDING LIGHT SWITCH S1-5 BURNSDR DALA2016052304115Lamp · inoperativeFWD GALLEY EMERGENCY AISLE LIGHTS INOPERATIVE. REPLACED LAMPS IAW AMM 33-53-01-401.SDR DALA2016051904048Battery Pack · inoperativeEMERGENCY CEILING LIGHTS IN FIRST CLASS INOPERATIVE. REPLACED BOTH BATTERIES IN BATTERY PACK ASSY.SDR DALA2016051904020Battery Pack · inoperativeCEILING EMERGENCY LIGHTS OUT AT SEATS 22C, 24C, 24D, AND 25C. REPLACED BOTH BATTERIES IN POWER PACK. REF AMM 33-53-00. OPS CHECK OK. PN ON 2 AD-4002P BATTERIES.SDR DALA2016111108698Panel · corrodedCORROSION ON T/E PANEL STA XA=400 AT LT WING. REPLACED PANEL 5912737-503.SDR DALA2016051703967Frame · corrodedCORROSION ON FRAME ON BS 1322 AND LONGERON 30. DAMAGE WAS CUT OUT IAW SRM 53-03, FIG 2A, FIG 3. HFEC WAS PERFORMED ON CUTOUT AREA, NO CRACKS WERE FOUND IAW NDT-SPM 06-10-01-001. NEW ANGLES -7-3 SECTION FILLER FRAME WERE DRILLED AND ADJUSTED IAW SRM 51-10-4.SDR DALA2016051703966Skin · crackedFUSELAGE EXTERIOR SKIN HAS 1" CRACK FROM FASTENER AT BS 1418 JUST BELOW STR 2 LT. REPAIRED IAW PRI 546964-14AD, REV 0 AND COMPLY WITH ER/A 546964-14AD, REV ORIGINAL.SDR DALA2016051603938Wire Harness · failedEMERGENCY LIGHT AT 14DE INOPERATIVE. REPLACED HARNESS AT SEAT 14DE IW AMM 33-52.SDR DALA2016051603962Connector · disconnectedEMERGENCY LIGHT OUT SEAT 29ED. RECONNECTED WIRE CLIP CONNECTOR AT ROW 29ED. OPS CHECKED GOOD. OK FOR SERVICE.SDR DALA2016051603961Battery Pack · inoperativeEMERGENCY LIGHTS IN TAIL COMPARTMENT INOPERATIVE. REPLACED FUSE IN BATTERY PACK, CHECKS GOOD, IAW AMM 33-53.SDR DALA2016051603960Battery Pack · inoperativeOVERHEAD EMERGENCY LIGHTS ROW 16-19 INOPERATIVE. R & R BATTERIES IAW AMM 33-53-00. OPS CHECKED GOOD.SDR DALA2016051603936Handle · no testTAILCONE FUNCTIONAL IAW AMDS 5350-01077-0101, STEP 11D. FAILED INTERIOR HANDLE PULL TEST 37LBS. SEE NR FOR ADDITIONAL INFORMATION 036-0001:5350-01077-0101/007 00009 REINSTALLED AND TESTED TAIL CONE IAW AMM 53- 53-00, WITHIN LIMITS, 27LBS.SDR DALA2016051603935Release Mech · failedTAILCONE RELEASE MECHANISM CAM FAILED TORQUE CHECK OF AMDS 5350-01077-0101, STEP NR 12. SEE NR FOR ADDITIONAL INFORMATION 036-0001:5350-01077-0101/005 00007. REPLACED IAW AMM 53-53-02, AJUSTED AND TORQUED.SDR DALA2016051403933Tab · bentAWR BENT OTBD EDGE OF RT ELEVATOR CONTROL TAB. RT ELEVATOR CONTROL TAB WAS REPAIRED IAW SRM 55-04, PAR 3 AND CARD 2000-8149-17, JOB 000-0031.SDR DALA2016051603934Vane · dentedSEVERAL DENTS ON REPAIR DOUBLER AT LT WING INBD FLAP INBD GUIDE VANE LOWER SURFACE. LT WING IBD FLAP INBD WAS REPAIRED IAW ERA 545145-14, REV ORIGINAL.SDR DALA2016051303906Battery Pack · inoperativeRT FORWARD OVERWING EXIT EMERGENCY IDENTIFIER INOPERATIVE. REPLACED BATTERIES IN POWER SUPPLY REF AMM 33-53-00. OPS NORMAL.SDR DALA2016051303905Power Supply · inoperativeROWS 16-25, EMERGENCY CEILING LIGHTS INOPERATIVE. REPLACED POWER SUPPLY AND BATTERIES FOR APPLICABLE LIGHTS REF AMM 33-53-00. OPS NORMAL.SDR DALA2016051303904Floor Support · crackedCRACK ON FLOOR SUPPORT BETWEEN BS 1271 AND 1287 X=3. FLOOR SUPPORT WAS REMOVED IAW SRM 51-30-2, DOUBLERS REPAIRS WERE FABRICATED IAW SRM 53-01, FIG 2. DOUBLERS WERE INSTALLED IAW SRM 51-30-2, THE FLOOR SUPPORT WAS INSTALLED IAW SRM 51-30-2.SDR DALA2016051203902Connector · damagedSEAT ROW 34ED EMERGENCY LIGHT INOPERATIVE. REPLACED PIGTAIL LIGHT ASSEMBLY, OPS NOW OK IAW AMM 33-51.SDR DALA2016051203900Block · damagedTAIL INTERIOR, TAIL CONE RELEASE LOCK CABLE BLOCK IS NOT .5" AWAY FROM TUBING, CONDUIT, AS REQUIRED IAW STEP 7. OPS CHECKED GOOD IAW AMDS 5350-01077-0101.SDR DALA2016051103855Door · damagedFUELING DOOR FOUND OPEN AND RIPPED AT STRUT. R & R REFUEL DOOR. OK FOR SERVICE.SDR DALA2016051103859Rib · crackedCRACKED RIB ON LT WING L/E BS XRS 324. STOP DRILL ON RIB IAW SRM 51-01, PAR 21, REPAIR. PARTS WERE FABRICATED IAW 57-06 B, FIG 18, REPAIR. PARTS WERE TREATED AND PAINTED IAW SRM 51-10-3, PAR 14, 21. REPAIR PARTS WERE INSTALLED IAW SRM 51-30-5.SDR DALA2016051103858Skin · crackedSKIN IS CRACKED JUST ABOVE THE PYLON. FWD OF AFT ENGINE MOUNT. ACCOMPLISHED HFEC TO IDENTIFY ENDS OF CRACKS IAW NDTSPM 06-10-01.00. ACCOMPLISHED SECTION 1 OF ER/A 546967-14.SDR DALA2016051703968Door · lack of lubeDURING TAILCONE RELEASE FUCTIONAL CHECK FOUND ARMING HANDLE HARD TO ROTATE. LUBED DOOR IAW AMM 12-21. CONFIRMED RIGGING AND RELEASE FORCE IAW AMM 52-12. OPS CHECK GOOD.SDR DALA2016051003857Scuff Plate · corrodedMID CARGO BAY DOOR LOWER JAMB UNDER ENTERY SCUFF PLATE CORRODED. REPAIRED IAW ER/A 499523-14MA, REV O.SDR DALA2016050903840Connector · disconnectedTHE CREW OF FLIGHT 2459, FOUND SEAT 14D EMERGENCY LIGHT INOPERATIVE. MAINTENANCE RESEATED A PLUG PIN AND THE LIGHT CHECKED OK.SDR DALA2016051003838Frame · crackedCRACKED FRAME BS 1497 LONGERONS 18L-19L IN AFT ACCESSORY COMPARTMENT. FRAME REPAIRED IAW ETI-88-16-190, REV 1 AND ER/A 545159-14, REV ORIGINAL.SDR DALA2016051003837Threshold · corrodedFOUND ON "OK TO TREAT", L1 DOOR, THRESHOLD, INBD THRESHOLD/FLOORBOARD SUPPORT, 4" FROM DOOR OPENING, CORRODED, IN MULTIPLE AREAS ALONG ENTIRE LENGTH OF SUPPORT. TREATED PRIMED AND PAINTED AND INSTALLED IAW DWG 9936534.SDR DALA2016050903836Skin · damagedDUE PRI 546901-14: FOUND 2 PULLED FASTENERS AT BS 229 BETWEEN 29RT AND 30RT. C/W PRI 546901-14, REV 0,1, 2, 3. C/W PRI 546901-14, REV 4, 8 MAY 16 AT 2230E. VERIFIED ERA 546901-14, REV ORIGINAL MATCHES PRI 546901-14, REV 0,1,2,3,4 8TH MAY 16 AT 2230E.SDR DALA2016111108699Splice Strap · corrodedER/A 546901-14 WAS ISSUED TO ADDRESS CORROSION TO THE SPLICE STRAP COMMON TO THE FUSELAGE BUTT SPLICE AT STA 229.SDR DALA2016050903839Battery Pack · inoperativeTHE FLIGHT CREW OF FLIGHT 1140 FOUND THAT THE EMERGENCY LIGHTS AT 2L OVERHEAD WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES FOR 2L EMERGENCY LIGHTS. THE LIGHTS CHECKS OK.SDR DALA2016050903804Access Panel · corrodedCORROSION AND WEAR ON SEATING AREA OF SECONDARY ACCESS PANELS, 1409C, 1410C AT RT WING. HEATER BLANKET WAS REPLACED IAW AMM 30-80-02, PAGE BLOOCK 401.SDR DALA2016050903803Access Panel · corrodedCORROSION ON SEATING AREA OF SECONDARY ACCESS PANELS, 1303C, 1307C AT LT WING. HEATER BLANKET WAS REPLACED IAW AMM 30-80-02, PAGEBLOCK 401.
Back to Mcdonnell Douglas MD-88