Mcdonnell Douglas MD-88
Service difficulty reports · 21,991
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD88' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD88' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2015082405187Battery Pack · inoperativeMAINTENANCE FOUND AFT OVERWING UPPER SIDEWALL EXIT LIGHTS INOPERATIVE. POWER SUPPLY BATTERIES WERE REPLACED IAW MM 33-50.SDR DALA2015082205169Cusp Web · corrodedCORROSION ON REPAIR DOUBLER OF THE CUSP WEB BS 598 - 617 BETWEEN LBL 54 TO 60. THE CUSP WEB WAS REPLACED IAW SRM 53-05, FIG 131A.SDR DALA2015082205168Rib · corrodedCORROSION ON HOLES OF RIBS BS XOS=380 AND XOS=429 AT LT WING SLAT PANEL NR 4. CORROSION ON HOLES OF RIB BS XOS=429 OF SLAT PANEL 4 WAS REPAIRED IAW SRM 57-02, PAR 9 AND BS XOS=380 WAS REPAIRED WITH ER/A 537759-14, REV ORIGINAL.SDR DALA2015082205167Access Panel · corrodedCORROSION ON COUNTERSINK AND SETLEMENT SURFACE AT RT WING ACCESS PANEL 1472C. THE ACCESS PANEL WAS REPLACED.SDR DALA2015082205158Floor Panel · delaminatedDELAMINATED FLOOR PANEL. THE FLOOR PANEL WAS FABRICATED IAW AMM 53-20-01-201.SDR DALA2015082205157Guide Vane · wornWEAR ON INBD EDGE UPPER & LWR SIDE OF T/E AT RT WING OTBD FLAP, OTBD GUIDE VANE. REPAIRED IAW SRM 57-03D, PAR 11.SDR DALA2015082105145Cusp Web · corrodedCORROSION ON RT CUSP WEB IN BS 1276 BETWEEN RBL 54 - 60. THE CUSP WEB WAS REPAIRED IAW SRM 53-05, FIG 131A-14, 51-10-3 PAR 14-21, AND 51-30-2.SDR DALA2015082105141Cusp Web · crackedCORROSION ON CUSP WEB OUT OF LIMITS LBL 54 TO 60 BETWEEN BS 706-712IN. CUSP WEB REPAIRED IAW SRM 53-05, FIG 131A-7, SHEET 1.SDR DALA2016081406109Skin · crackedCRACKS WERE FOUND EMANATING FROM 3 FASTENER HOLES AT BS 1380 AND L-14R. ERA 538627-14, SECTION I ISSUED FOR REPAIR ALONG LONGERON 14R SKIN LAP JOINT, AT STA 1380.SDR DALA2015082705247Access Panel · corrodedCORROSION ON COUNTERSINK OF ACCESS PANEL 1307C, LT WING. THE ACCESS PANEL WAS REPLACED.SDR DALA2015082505196Access Panel · corrodedCORROSION ON SETTLEMENT AREA OF FUEL ACCESS PLATE 1371C. THE ACCESS PANEL WAS REPLACED.SDR DALA2015082005149Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY EXIT SIGN FOR THE AFT OVERWING HATCH WAS INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. OPERATIONAL CHECK WAS GOOD.SDR DALA2015082005147Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHTS AT ROWS 2-10 OF THE CABIN WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACKS FOR THE NOTED LIGHTED AREAS AND THE OPS CHECKED GOOD.SDR DALA2015082105144Access Panel · corrodedCORROSION ON COUNTERSINK OF FUEL ACCESS PANEL 1478C. REPLACED THE ACCESS PANEL.SDR DALA2015082105143Access Panel · corrodedCORROSION ON COUNTERSINK AND SETTLEMENT AREA OF FUEL ACCESS PANEL 1454C. THE ACCESS PANEL WAS REPLACED.SDR DALA2015082105142Access Panel · corrodedCORROSION ON COUNTERSINK AND SETTLEMENT AREA OF ACCESS PANEL 1456C. THE ACCESS PANEL WAS REPLACED AND WILL BE INSTALLED UNDER CARD 2800-0390.SDR DALA2015082105140Skin · crackedCRACKED SKIN ON SLAT PANEL NR 1 AT RT WING, XIS=136.421. CRACK WAS REPAIRED IAW SRM 57-01, FIG 3.SDR DALA2015082105139Skin · damagedDAMAGE METALLIZATED COAT OF RUDDER TAB. METALLIZED COAT OF RUDDER TAB WAS REPAIRED IAW SRM 51-70-1A, PAR 23 AND CARD 200-8149-17, JOB 000-0022.SDR DALA2015082105138Skin · damagedELONGATED HOLES ON LOWER AND UPPER SKIN AT LT WING TIP. DAMAGE HOLES WERE REPAIRED IAW EA 09-478904-14MA, REV : ORIG.SDR DALA2015082105137Skin · damagedELONGATED HOLES ON UPPER AND LOWER SKIN AT RT WING TIP. DAMAGE HOLES REPAIRED IAW EA 09-478904-14 MA, REV ORIG.SDR DALA2015082105136Cusp Web · corrodedCORROSION ON CUSP WEB OUT OF LIMITS X=54 TO X=60 BETWEEN BS Y=605-607, LT PAX CABIN. CUSP WEB WAS REPAIRED IAW SRM 53-05, 131A-6, SHEET 1, 51-30-1, 51-30-2, 51-30-5.SDR DALA2015082105134Floor Panel · delaminatedDELAMINATED FLOOR PANEL NR 200A. FLOOR PANEL NR 200A WAS REPAIRED IAW SRM 51-90-0, PAR 8 K.SDR WX0A2015082172826Fuel Cap · missingRAMPERS INFORMED FUELING PANEL WAS OPEN PULLING INTO GATE. FUEL CAP MISSING. EVIDENCE OF FUEL CAP BANGING AGAINST UNDERSIDE OF WING BEHIND FUEL PANEL BEFORE DEPARTING ACFT. DEFERRED RT WING FUEL CAP IAW MEL 28-17 SIT 1 CAT D AS AUTHORIZATION 19256 DATE DUE SDR DALA2015082005079Cusp Web · corrodedCORROSION OUT OF LIMITS AFTER CORROSION REMOVAL ON RT CUSP WEB FROM BS 543-558 AND BS 559-570 X -54 TO X -60. AREA OUT OF LIMITS WAS REPAIRED IAW SRM 53-05, FIG 131A-7 AND CIC WILL BE APPLIED IAW NRC 20000072167 CARD, NR 18, AC ZONE 201.SDR DALA2015082005078Cusp Web · corrodedCORROSION ON CUSP WEB BETWEEN BS 1257-1267 AND BETWEEN X -54 TO X -60 . REPAIR WAS ACCOMPLISHED IAW SRM 53-05, FIG 131A-B.SDR DALA2015082005074Frame · crackedCRACKED FRAME ON BS 1322 OVER LONGERON 17L. FRAME WAS REPAIR IAW ER/A 493697-14 MA REV B.SDR DALA2015082005077Cusp Web · corrodedCORROSION ON CUSP WEB OUT OF LIMITS X 54 TO X 60 BETWEEN BS 875 - 877, LT PAX CABIN. CUSP WEB WAS PREPARED IAW SRM 51-30-2, 53-05, FIG 131A-3, SHEET 1, 51-10-3 P, 14, 21.SDR DALA2015082005075Vane · chafedLT WING, CENTER FLAP VANE UPPER SURFACE CHAFED THRU JUST AFT OF INBD FLT SPOILER OTBD END. REPLACE DOUBLER REF SRM 51-70-02 DRD.SDR DALA2015082005073Cusp Web · corrodedCORROSION ON REPAIR DOUBLER ON LT CUSP WEB BS 900 BETWEEN X 54 - 60. REPAIR WAS REPLACED IAW SRM 53-05, FIG 131A.SDR DALA2015082005071Rib · corrodedCORROSION ON RIBS XOS=286 AND XOS=332, REPAIRED IAW SRM 57-02, PAR 9.SDR DALA2015082005070Intercostal · crackedCRACKED INTERCOSTAL BS 1355 AND X -22 AT RT AFT LAVATORY AREA. CRACK WAS STOP DRILL IAW SRM 51-01, PAR 21, PARTS WERE FABRICATED, TREATED AND PAINTED IAW SRM 51-10-3, PAR 14 AND 21, 53-01 FIG 2, NEW PARTS WERE INSTALLED IAW SRM 51-30-2 AND 51-30-5.SDR DALA2015082005069Cusp Web · corrodedCORROSION ON CUSP WEB BS 237 BETWEEN X=-54 / X=-60. DAMAGE WAS REMOVED TO REPAIR THE DAMAGED AREA IAW SRM 53-05. THEN, THE TRIM WAS INSPECTED FOR CRACKS AND NO CRACKS WERE FOUND. AFTER THAT, REPAIR PARTS WERE FABRICATED IAW SRM 53-05, FIG 131A-10 TO BE TRESDR DALA2015081905068Hinge · wornWEAR ON HINGES XET= 119.7 AT LT ELEVATOR T/E. HINGE WAS REMOVED, NEW HINGE WAS DRILLED NEW HINGE WAS TREATED AND PAINTED, NEW HINGE WAS INSTALLED IAW SRM 51-30-2, 51-30-1, 51-10-4, 51-10-3 PAR 14 AND 21.SDR DALA2015082105133Longeron · crackedCRACKED LONGERON 4R BETWEEN BS 522 - 524. LONGERON WAS REPAIRED IAW SRM 53-02, FIG 18, 51-30-2, 51-30-5 AND 51-10-3 PARR 14, 21.SDR DALA2015082005095Angle · crackedSTABILIZER SUPPORT STRUCTURE LT ANGLE CRACKED. REMOVED ANGLE, REPLACEMENT ANGLE WAS FABRICATED FROM .090, 7075-0, HEAT TREATED TO T6 CONDITION. ON RO 702799 IAW DWG 9911808, DRILL AND TRIMMED ANGLE. TREATED AND PAINTED. INSTALLED NEW ANGLE ALL FASTENERS SECSDR DALA2015082005094Angle · crackedDURING JACKSCREW INSPECTION FOUND VERTICAL STABILIZER SUPPORT STRUCTURE RT ANGLE CRACKED. ANGLE WAS FABRICATED FROM .090 7075-0 AND HEAT TREATED TO T6 ON RO 702799 IAW DWG 9911808. TREATED AND PAINTED. INSTALLED NEW ANGLE ALL FASTNERS SECURED REF SRM 51-30-SDR DALA2015081905093Door · crackedCRACK ON DOOR SLAT TRACK NR 4 AT RT WING. SLAT TRACK DOOR NR 4 RT WAS REPLACED IAW ERA: 512356-14MA, REV ORIGINAL ERA 512356-14MA, REV ORIGINAL.SDR DALA2015081905089Skin · damagedOUT OF LIMITS REWORKED AREA ON FUSELAGE SKIN BETWEEN BS 430 - 440 AND LONGERONS 23 - 25L. FUSELAGE SKIN REPAIRED IAW SRM 53-04-2, FIGURE 2, SHEET 6.SDR DALA2015081905088Cusp Web · corrodedCORROSION ON REPAIR DOUBLER OF LT CUSP WEB BETWEEN BS 1238-1250 AND BETWEEN X 54 - 60 . REPAIR DOUBLER WAS REPLACED IAW SRM 53-05, FIG 131A-6.SDR DALA2015082005076Tab · damagedFOUND LT ELEVATOR INBD TAB WITH LIGHTNING STRIKE AND DAMAGE TO T/E OF TRIM TAB OF MORE THAN 6". R & R LT ELEVATOR CONTROL TAB IAW AMDS CARD 2730-4634.SDR DALA2015082005072Rib · corrodedCORROSION ON RIB XOS=83 AND HOLES XOS=166 AT LT WING SLAT PANEL NR 1. CORROSION ON HOLES RIB BS XOS=83 AND XOS=166 AT LT WING SLAT PANEL NR 1 WAS REMOVED IAW SRM 57-02, PAR 9.SDR WX0A2015081972823Unknown · odorBURNING SMELL NOTED DURING TAKEOFF & APPROX 5 MINS AFTER TAKEOFF BY ALL CREW INCLUDING FLIGHT ATTENDANTS. INSPECTED SYS & OPERATIONS IAW MM 21-51-00. NO ABNORMALITIES NOTED.SDR DALA2015081805016Wire · pulledDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHTING AT SEAT 24DE IN THE CABIN WAS INOPERATIVE. MAINTENANCE FOUND WIRES PULLED OUT OF THE CONNECTOR. THE CONNECTOR WAS REPLACED AND THE SYSTEM RETURNED TO NORMAL OPERATION.SDR WX0A2015082472824Engine · overtempCLIMBING OUT OF 16,000 FEET THE CREW NOTICED THAT THEY HAD AN INDICATION OF OIL TEMP HIGH ON THE NR 1 ENG. THE OIL TEMP WAS 145 & THE FUEL TEMP WAS 99. THE AUTO FUEL HEAT SYS WAS ON, BUT HEAT WAS NOT BEING APPLIED AT THE TIME. THE CREW DID THE QRH PROCEDURESDR DALA2015081905148Clamp · looseCREW SMELLED AN ELECTRICAL ODOR DURING CLIMBOUT. DISSAPATED AT CRUISE. ODOR CAME BACK DURING DESCENT. FOLLOWED MM 05-50-01 & NO GO ODI PREVIOUS SITE & AMDS CARD 2120-2367. NO SOURCE OF ODOR IDENTIFIED. PERFORMED FULL DUCT BURNOUT IAW MM 21-20-02. NO DEFSDR DALA2015081805146Autothrottle Sys · malfunctionedON TAKEOFF ROLL, AUTO THROTTLE SYSTEM DEACTIVATED SHORTLY AFTER WE HAD ELECTRICAL ODOR THAT DISIPATED A FEW THOUSAND FEET AFTER T/O. WE RECEIVED THE SAME ELECTRICAL ODOR ON DESCENT. NO SMOKE OR FUMES PRESENT. T/S AND FOUND NO DEFECTS IN FWD E/E BAY. NO DEFSDR DALA2015082105135Web · puncturedPUNCTURES ON FLOOR MEMBRANE X54 BETWEEN BS 160 - 200 AT LT AREA. DAMAGE FASTENERS WERE REMOVED, DOUBLER WAS FABRICATED, TREATED, PAINTED AND INSTALLED IAW SRM 51-30-2, 53-01, FIG 2 , 51-10-3 PAGE 14 AND 21.SDR DALA2015081805129Longeron · crackedCRACKED LONGERON 5L BS 1003. LONGERON SECTION WAS REMOVED, AND A NEW LONGERON SECTION AND SPLICES WERE FABRICATED, DRILLED, TREATED, PAINTED AND INSTALLED IAW SRM 51-30-1, 51-30-2, 51-30-5, 53-02, FIG 18, 51-10-4, AND 51-10-3, PAR 14 AND 21.SDR DALA2015081805062Skin · gougedGOUGE ON LT INBD FLAP, INBD SKIN LOWER SECTION BS XCW=76-78. REPAIRED IAW SRM 57-03D, FIG 8, SRM 51-10-3, PAR 14, 21, AND SRM 51-30-8.SDR DALA2015081805061Access Panel · corrodedCORROSION ON COUNTERSINK AND SETTLEMENT AREA OF FUEL ACCESS NR 1410C. THE ACCESS PLATE WAS REPLACED.
Back to Mcdonnell Douglas MD-88