Nihon YS-11A-500
Service difficulty reports · 117
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'YS11A500' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'YS11A500' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ABXA9501005Floorbeam · corrodedDURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 840. REPAIRED IAW REA Y153-13321-MR.SDR ABXA9501000Floorbeam · corrodedDURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 9180. REPAIRED IAW REA Y153-13321-MR.SDR ABXA9501034Floorbeam · corrodedDURING C-CHECK, THE FLOORBEAM AT STA 6600 WAS FOUND CORRODED. REPAIRED IAW REA Y153-13320-MR.SDR ABXA9501031Support · corrodedDURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 840 AND 8080 LBL 300 WAS FOUND CORRODED. REPAIRED IAW REA Y153-13320-MR.SDR ABXA9501009Floorbeam · corrodedDURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 6120. REPAIRED IAW REA Y153-13321-MR.SDR ABXA9501004Floorbeam · corrodedDURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 2550. REPAIRED IAW REA Y153-13321-MR.SDR ABXA9501003Floorbeam · corrodedDURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 5430. REPAIRED IAW REA Y153-13321-MR.SDR ABXA9501002Floorbeam · corrodedDURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 3030. REPAIRED IAW REA Y153-13321-MR.SDR ABXA9501001Floorbeam · corrodedDURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 5430. REPAIRED IAW REA Y153-13321-MR.SDR ABXA9500999Floorbeam · corrodedDURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 2280. REPAIRED IAW REA Y153-13321-MR.SDR ABXA9500998Floorbeam · corrodedDURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 2095. REPAIRED IAW REA Y153-13321-MR.SDR ABXA9500997Floorbeam · corrodedDURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 5160. REPAIRED IAW REA Y153-13321-MR.SDR ABXA9500996Floorbeam · corrodedDURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 1535. REPAIRED IAW REA Y153-13321-MR.SDR ABXA9500995Floorbeam · corrodedDURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 4470. REPAIRED IAW REA Y153-13321-MR.SDR ABXA9501036Support · damagedDURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 4680 AND 5160 LBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.SDR ABXA9501029Support · damagedDURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 6120 AND 6600 RBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.SDR ABXA9501028Support · damagedDURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 7080 AND 7580 LBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.SDR ABXA9501027Support · damagedDURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 3720 AND 4200 LBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.SDR ABXA9501026Support · damagedDURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 7580 AND 8080 RBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.SDR ABXA9501025Support · damagedDURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 7580 AND 8080 LBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.SDR ABXA9501024Support · damagedDURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 7080 AND 7580 RBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.SDR ABXA9501023Support · damagedDURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 4680 AND 5160 RBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.SDR ABXA9501022Support · damagedDURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 5160 AND 5640 LBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.SDR ABXA9501021Support · damagedDURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 6600 AND 7080 RBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.SDR ABXA9501020Support · damagedDURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 4680 AND 4200 RBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.SDR ABXA9501019Support · damagedDURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 5160 AND 5640 RBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.SDR ABXA9501018Support · damagedDURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 2760 AND 3240 RBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.SDR ABXA9501017Support · damagedDURING C-CHECK THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 3720 AND 4200 RBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.SDR ABXA9501016Support · damagedDURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 7580 AND 8080 RBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.SDR ABXA9501015Support · damagedDURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 2280 AND 2760 RBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.SDR ABXA9500994Floorbeam · corrodedDURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 6390. REPAIRED IAW REA Y153-13321-MR.SDR ABXA9500993Floorbeam · corrodedDURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 3720. REPAIRED IAW REA Y153-13321-MR.SDR ABXA9501011Floorbeam · corrodedDURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 2760. REPAIRED IAW REA Y153-13321-MR.SDR ABXA9500992Floorbeam · corrodedDURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 4200. REPAIRED IAW REA Y153-13321-MR.SDR ABXA9500897Floor Beam · corrodedDURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A LONGITUDINAL FLOOR BEAM AT STA 7580. REPAIRED I/A/W ABX REA Y153 13209-MR.SDR ABXA9500895Air Distr · smokingSMOKE IN COCKPIT FROM BLEED HEAT, DRY TAKEOFF. DEFERRED NR 2 ENGINE BLEED HEAT I/A/W YS-11 M.E.L. 21-13. MAINTENANCE PROCEDURES COMPLIED WITH, PLACARD INSTALLED. D.I. NR 910-076.SDR ABXA9500911Floor Beam · corrodedDURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A FLOOR BEAM AT STA 7580. REPAIRED I/A/W ABX REA Y153 13211-MR.SDR ABXA9500902Floor Beam · corrodedDURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A FLOOR BEAM AT STA 6600. REPAIRED I/A/W ABX REA Y153 13209-MR.SDR ABXA9500896Intercostal · corrodedDURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A LONGITUDINAL FLOOR BEAM AT STA 6120. REPAIRED I/A/W ABX REA Y153 13209-MR.SDR ABXA9500892Air Distr · smokeSMOKE IN CABIN AND COCKPIT FROM BLEED HEAT SYSTEM. SMOKE WAS BAD ENOUGH TO CAUSE MINOR THROAT IRRITATION, BUT NOT ENOUGH TO USE SMOKE EQUIPMENT. TRIED TWICE, TOOK 3 TO 5 MINUTES FOR SMOKE TO START. VISUALLY INSPECTED BLEED AIR DUCTING TO COCKPIT, RAN ENGINESDR ABXA9500912Floor Beam · corrodedDURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A FLOOR BEAM AT STA 4680. REPAIRED I/A/W ABX REA Y153 13211-MR.SDR ABXA9500910Floor Beam · corrodedDURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A FLOOR BEAM AT STA 4680. REPAIRED I/A/W ABX REA Y153 13211-MR.SDR ABXA9500904Floor Beam · corrodedDURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A FLOOR BEAM AT STA 8080. REPAIRED I/A/W ABX REA Y153 13193-MR.SDR ABXA9500903Floor Beam · corrodedDURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A FLOOR BEAM AT STA 6600. REPAIRED I/A/W ABX REA Y153 13193-MR.SDR ABXA9500901Floor Beam · corrodedDURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A FLOOR BEAM AT STA 6120. REPAIRED I/A/W ABX REA Y153 13209-MR.SDR ABXA9500899Floor Beam · corrodedDURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A LONGITUDINAL FLOOR BEAM AT STA 4680. REPAIRED I/A/W ABX REA Y153 13209-MR.SDR ABXA9500900Floor Beam · corrodedDURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A FLOOR BEAM AT STA 4200. REPAIRED I/A/W ABX REA Y153 13209-MR.SDR ABXA9500898Floor Beam · corrodedDURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A LONGITUDINAL FLOOR BEAM AT STA 4200. REPAIRED I/A/W ABX REA Y153 13209-MR.SDR ABX9500905Frame · corrodedDURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A FUSELAGE FRAME AT STA 8080 BETWEEN LONGERONS 30LT TO 28RT. REPAIRED I/A/W YS-11 SRM 53-3-2.SDR ABXA9500909Floor Beam · corrodedDURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A FLOOR BEAM AT STA 3240. REPAIRED I/A/W ABX REA Y153 13211-MR.
Back to Nihon YS-11A-500