SDR NSVA200600131Pump · failedHYDRAULIC PUMP FAILURE DURING POSITIVE RATE GEAR UP: NO MOTOR ENGAGE, ENGAGE AFTER TOUCH DOWN. REMOVED AND REPLACED HYDRAULIC PUMP AMM 29-10-10-4, OPS CHECK GOOD, P/N OFF/ON 40185-02 S/N OFF 1068, S/N ON H78. NO LEAKS NOTED.SDR MALA060562Panel · animal strikePANEL 151CB HAS COMPOSITE DAMAGE FROM DEER STIKE. REPAIRED IAW EOS51031, THIS IS A MAJOR REPAIR.SDR MALA060561Fairing · damagedLT FAIRING PANEL 197BL SUSTAINED DEER STRIKE AND REQUIRES REPAIR. REPAIRED IAW EOS51031. THIS IS A MAJOR REPAIR.SDR MALA060538Relay · malfunctionedLEFT HAND ENGINE SHUTDOWN ON FINAL AT APPROXIMATELY 1000 FT. OPS CHECK OF AUTO COARSEN SYSTEM GOOD. FOR PRECAUTION REMOVED AND REPLACED RELAY 68KF, REMOVED AND REPLACED AUTO COARSEN SWITCHER UNIT P/N 8581, S/N OFF 362, ON 353. REMOVED AND REPLACED LT & RT ASDR NSVA200600133Throttle Control · warning lightFLIGHT IDLE STOP OPEN LIGHT CAME ON DURING TAKEOFF. REMOVED AND REPLACED THROTTLE QUADRANT IAW AMM 76-10-05, PN ON/OFF 53170-4 SN ON 635, SN OFF 064, OPS CHECK GOOD.SDR NSVA200600129Control Valve · malfunctionedFLAPS WOULD NOT EXTEND TO 15 DEGREES WHEN SELECTED. REMOVED AND REPLACED FLAP CONTROL VALVE IAW SAMM 27-51-15-04. PERFORMED OPERATIONAL CK OF FLAPS. OPS CK GOOD P/N ON HP1416100-5 S/N ON 1253 S/N OFF 1203.SDR MALA060537Control Valve · faultyAFTER LANDING GEAR WERE EXTENDED FOR LANDING, THERE WERE NO DOWN AND LOCKED LIGHTS AND THE F7 CIRCUIT BREAKER WAS POPPED. FOLLOWED THE QRH AND GOT THREE GREENS. THE CREW AND DISPATCH ELECTED TO RETURN TO MEM. REMOVED AND REPLACED LANDING GEAR CONTROL VALVE SDR MALA060536Battery Pack · failedFAILED CAPACITY CHECK PER BFGOODRICH CMM WO 413144. REPLACED BATTERY PACK.SDR MALA060535Elevator · damagedTHE RIGHT ELEVATOR, P/N 7255201-654, S/N 2060, HAD COMPOSITE DAMAGE. REPAIRED IAW MESABA EO S51031. REF: EAMS WORK ORDER 214335 TASK 3506.SDR MALA060534Elevator · damagedTHE LEFT ELEVATOR, P/N 7255201-655, S/N 2051, HAD COMPOSITE DAMAGE. REPAIRED IAW MESABA EO S51031. REF: EAMS WORK ORDER 214335 TASK 3505.SDR MALA060600Skin · gougedREPAIRED LT ELEVATOR TRAILING EDGE GOUGE FROM TRIM TAB OB HINGE IAW EO NR S51031 WO 214335/3505.SDR MALA060530Seat Track · corrodedDURING 2 YEAR CHECK IN BNA, FOUND SEAT TRACK AT BLO BETWEEN FS 294 AND 300 IS CORRODED OUT OF LIMITS. THE DAMAGE HAS BEEN REPAIRED IAW MESABA EO NR S53342. REF: EAMS WORK ORDER 214335 TASK 1507.SDR MALA060529Seat Track · corrodedDURING 2 YEAR CHECK IN BNA, FOUND SEAT TRACK AT LBL 18.3, BETWEEN FS 294 AND 300 IS CORRODED OUT OF LIMITS. THE DAMAGE HAS BEEN REPAIRED IAW MESABA EO NR S53342. REF: EAMS WORK ORDER 214335 TASK 1508.SDR MALA060531Web · corrodedDURING 2 YEAR CHECK IN BNA, FOUND FLOOR REINFORCEMENT WEB, BETWEEN FS 288 AND 294 IS CORRODED OUT OF LIMITS IN TWO AREAS. THE DAMAGE HAS BEEN REPAIRED IAW MESABA EO NR S53362. REF: EAMS WORK ORDER 214335 TASK 1505.SDR NSVA200600125Light · odorSTRONG BURNING ODOR COMING FROM AFT CABIN. FOUND ODOR COMING FROM AFT OVERHEAD LIGHT. REMOVED OVERHEAD LIGHT AND INSPECTED, NO DEFECTS WERE NOTICED.SDR NSVA200600127Light · inoperativeEMERGENCY LIGHT AT RT PSU ABOVE SEAT LOCATION 7 NOT ILLUMINATING. REMOVED AND REPLACED PSU ASSY IAW 25-25-10, OPS CHECK GOOD.SDR NSVA200600126Bulb · inoperativeBOTH FLOOR PROXIMITY EMERGENCY LIGHTS AT SEAT 11 AISLE WERE DISCOVERED NOT ILLUMINATING ON LINE CHECK. REMOVED AND REPLACED LAMPS, OPS CHECK GOOD.SDR MALA060533Relay · malfunctionedEN ROUTE TO TRI THE AIRCRAFT IGNITION LIGHT ILLUMINATED WHEN UNCOMMANDED. THE FLIGHT RETURNED TO MEM. REPLACED RELAY 32PCSDR MALA060526Skin · dentedDURING 4 K CHECK IN BNA, FOUND LEFT ELEVATOR LEADING EDGE 333DB HAS A SMALL DENT ON THE UPPER SURFACE. REPAIRED IAW EO NR S51031. REF: EAMS WORK ORDER 214264 TASK 3508.SDR MALA060525Connector · brokenEMERGENCY AISLE PATH LIGHTING CONNECTOR IS BROKEN. THE DAMAGE HAS BEEN REPAIRED IAW SAAB 340 WIRING MANUAL 20-20-20.SDR MALA060519Seat Track · corrodedDURING 4K CHECK, FOUND SEAT TRACK AT LBL 18.3 BETWEEN FS 658.5 AND FS 686.888 IS CORRODED OUT OF LIMITS IN THE COIN SLOT AREA. THE DAMAGED SEAT TRACK HAS BEEN REMOVED AND REPLACED IAW MESABA EO NR S53060. REF: EAMS WORK ORDER 214264 TASK 1539.SDR PNSA060809Battery · failedCREW ABORTED TAKEOFF AT 90 KNOTS, WHEN BOTH EFIS SCREENS WENT BLANK AND HYDRAULIC PUMP CYCLED ON. MAINTENANCE REPLACED AIRCRAFT DC BATTERIES.SDR MALA060520Odor · detectedCREW REPORTED THAT AFTER THE START OF THE RIGHT ENGINE THE PAX AND FA COMPLAINED OF A BURNING SMELL IN THE CABIN. NO SMOKE WAS REPORTED. RAN ENGINE WITH LP, HP ON, ALL LIGHTS ON. NO BURNING SMELL NOTED. A/C GOOD FOR RETURN TO SERVICE.SDR SIMA200622801Power Supply · dischargedFOUND EMERGENCY EXIT IDENTIFIER 8A INOPERATIVE. TROUBLESHOT TO POWER SUPPLY 23LN. REMOVED AND INSTALLED EMERGENCY LIGHTING POWER SUPPLY 23LN, IAW AMM 33-50-10, OPS CHECK GOOD. RETURNED AIRCRAFT TO SERVICE. (M)SDR MALA060512Acm · odorGATE RETURN DUE TO SMOKE SMELL IN THE CABIN. DETERMINED ODOR DUE TO LT ACM FAILURE. REPLACED ACMSDR MALA060516Structure · chafedDURING 4 K CHECK IN BNA, FOUND LT ENGINE, LOWER FORWARD DECK IS CHAFED OUT OF LIMITS, AND HAS BEEN REPAIRED IAW MESABA EO NR S54095. REF: EAMS WORK ORDER 214264 TASK 4508.SDR MALA060517Seat Track · corrodedDURING 4K CHECK IN BNA, FOUND SEAT TRACK AT LBL 18.3 IS CORRODED OUT OF LIMITS BETWEEN FS 294 AND 304. THE DAMAGE HAS BEEN REPAIRED IAW MESABA EO#S53342. REF: EAMS WORK ORDER 214264 TASK 1554.SDR MALA060518Door Frame · corrodedDURING 4K CHECK IN BNA FOUND COCKPIT DOOR POST, AT LBL 10.5 IS CORRODED OUT OF LIMITS. THE DAMAGE HAS BEEN REPAIRED IAW MESABA EO#S53185. REF: EAMS WORK ORDER 214264 TASK 1556SDR MALA060515Skin · delaminatedDURING 4K CHECK IN BNA, FOUND LT ELEVATOR, P/N 7255201-653, S/N 2045, IS CHAFED ON THE OUTBOARD LEADING EDGE. THE DAMAGE HAS BEEN REPAIRED IAW MESABA EO NR S51031. REF: EAMS WORK ORDER 214265 TASK 3505.SDR MALA060514Seat Track · corrodedDURING 4K CHECK IN BNA, FOUND SEAT TRACK AT BLO IS CORRODED OUT OF LIMITS BETWEEN FS 294 AND 304. THE DAMAGE HAS BEEN REPAIRED IAW MESABA EO NR S53342. REF: EAMS WORK ORDER 214264 TASK 1552.SDR NSVA200600124Indicator · inoperativeDURING TAKEOFF ROLL, NO INDICATION ON CAPT'S AIRSPEED INDICATOR, F/O'S READING 70 KTS. RESEATED AIRSPEED INDICATOR CONNECTOR, OPS CHECK GOOD IAW 34-12-00-05.SDR NSVA200600123Switch · dirtyAUTOCOARSEN LIGHT ON CWP COMES FOR 2 - 3 SECONDS ON THEN GOES OFF. CLEANED PA SWITCHES ON BOTH ENGINES. RAN ENGS. SYS OPS CK GOOD, IAW MM 61-22-00-1.SDR NSVA200600122Ecu · malfunctionedL TORQUE GAUGE FLUCTUATES +/- 20 PERCENT FROM SET TORQUE, NO CHANGE IN ITT, NG OR FUEL FLOW, NO AUDIBLE CHANGE IN POWER, NO YAW MOVEMENT. IGNITION LIGHT TURNS ON TORQUE IS RESTORED. REMOVED AND REPLACED LEFT ENG DECU IAW 76-10-57-04. OPS CHECK GOOD, PN ON/OSDR NSVA200600121Power Supply · inoperativeDURING A LINE CHECK 1 INSPECTION, 5 FLOOR PROXIMITY LIGHTS WERE INOPERATIVE. EMERGENCY LIGHT POWER SUPPLY 24LN WAS REPLACED IAW COLGAN AIR WORKCARD 33-50-02S, PN ON 60-1321-1.SDR MALA060510Relay · malfunctionedON TAKEOFF, CREW EXPERIENCED FAILURE OF THE FLIGHT IDLE STOP SYSTEM AND RETURNED TO MEM. REPLACED RELAY 82KA. OPS CHECK GOOD.SDR MALA060511Wire Harness · damagedNOSE GEAR GREEN LIGHT INTERMITTENT AFTER EXTENSION. SUSPECT A LOOSE CABLE TO NOSE WHEEL DOWN INDICATOR. LIGHT ASSEMBLY GOES ON AND OFF ON IT'S OWN. REPLACED NOSE DOWN LOCK HARNESS ASSEMBLY PN AIR130900. OPS CHECK GOOD.SDR NSVA200600120Igniter · unknownABORTED TAKEOFF ITT RT ENGINE 935 AND CLIMBING. REPLACED OUTBOARD IGNITER AND OPS CHECKED GOOD IAW 72-00-00.SDR MALA060508Battery Pack · no testFAILED CAP CHECK PER BFGOODRICH CMM WO 412745. REPLACED BATTERY PACK.SDR MALA060506Duct · damagedRT ALPHA VANE LIGHT ILLUMINATED ON TAXI AND STRONG BURNING SMELL IN COCKPIT. REMOVED AND REPLACED CURRENT MONITOR. REPLACED RT ENGINE LOWER DUCT P/N NH24668-165, S/N ON L155348, RT ENGINE DEICE MODULE AND RT A/C GCU.SDR NSVA200600119Smoke Detector · malfunctionedCARGO DOOR LIGHT "ON" AFTER NR 2 ENGINE STARTED. REMOVED AND REPLACED NR 2 AFT SMOKE DETECTOR, OPS CHECK GOOD, PN ON/OFF CGAB1201-01, SN ON 537, SN OFF 435.SDR NSVA200600118Motor · malfunctionedHYD LIGHT ON AFTER TAKEOFF, MAIN ACCU 1000 PSI, LANDING GEAR DID NOT LOCK UP. REMOVED AND REPLACED HYD PUMP MOTOR IAW 29-10-075, PN ON/OFF 40185-02 SN ON H70, SN OFF I32.SDR MALA060502Power Supply · dischargedEMERGENCY LIGHTS 7LN, 9LN, 10LN, 11LN, 42LN, 43LN, 44LN INOP. FOUND POWER SUPPLY 20LN P/N 3301-51, S/N 2116 AT FAULT. REPLACED WITH SERVICEABLE UNIT.SDR MALA060501Door Frame · corrodedCOCKPIT DOOR POST, AT LBL 10.5 IS CORRODED OUT OF LIMITS. THE DAMAGE HAS BEEN REPAIRED IAW MESABA EO S53185. REF EAMS WORK ORDER 214210 TASK 1517.SDR NSVA200600117Smoke Detector · dirtyAVIONIC SMOKE ANNUNCIATOR ILLUMINATED IN FLIGHT TWICE. CLEANED AVIONIC SMOKE DETECTOR IAW 26-13-00. OPS CHECK GOOD. INSPECTED AVIONICS COMPONENT, NO SMOKE NOTED.SDR MALA060503Wire · chafedEMERGENCY CALL LIGHT ON PILOTS OVERHEAD PANEL WAS INOP WHEN EMERGENCY CALL BUTTON WAS PUSHED. LAMP TEST OK. FOUND WIRE RY63-24 CHAFED ALMOST THROUGH. REPLACED WIRE RY63-24 FROM CONNECTOR 91VPP9 TO RESISTOR 10RY.SDR NSVA200600116Engine · malfunctionedLEFT ENGINE TORQUE AT 105 PERCENT AND CTOT AT 94 PERCENT, PWR INITIAL AT 80 PERCENT, AIRCRAFT STARTED TO YAW, CREW ABORTED TAKEOFF. PERFORMED CTOT SYSTEM TEST, OPS CHECK GOOD.SDR MALA060496Panel · faultyAFTER TAKEOFF OBSERVED FLUCTUATIONS ON RT ENGINE. THIS OCCURRED WITH CTOT ON AND OFF AND PROP SYNC ON AND OFF. AIR RETURN. REMOVED AND REPLACED CTOT PANEL.SDR MALA060498Seat Track · corrodedTHE SEAT TRACK AT BL 0 IS CORRODED OUT OF LIMITS AT FS 641. THE DAMAGE HAS BEEN REPAIRED IAW MESABA EO S53078. REF EAMS WORK ORDER 214210 TASK 2514.SDR MALA060500Structure · chafedLT NACELLE, LOWER INLET DECK IS CHAFED OUT OF LIMITS. THE DAMAGE HAS BEEN REPAIRED IAW MESABA EO S54095. REF EAMS WORK ORDER 214211 TASK 4503.SDR MALA060499Seat Track · corrodedSEAT TRACK AT LBL 18.3, BETWEEN FS 297 AND 319 IS CORRODED OUT OF LIMITS. THE DAMAGE HAS BEEN REPAIRED IAW MESABA EO S53342. REF EAMS WORK ORDER 214210 TASK 1513.
Back to Saab 340B