Sikorsky/Carson Services S61N

Service difficulty reports · 287

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'S61N'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR 39LA2014041269Warning Light · illuminatedDURING CRUISE FLIGHT FROM FOB LIGHTNING THE NR 1 ENG ACCESSORY GEARBOX CHIP DETECTOR LIGHT ILLUMINATED. OASH WAS SOUTH OF OUR POSITION & WE DIVERTED THERE WITHOUT INCIDENT. NR 1 ENG ACCESSORY CHIP DETECTOR REMOVED & INSPECTED L DEBRIS ANNOTATED & MEASURED WApr 12, 2014 · N725JH · Skrsky S61N · Turbine Engine Accessory DriveSDR 39LA2014041068Warning Light · illuminatedDURING CRUISE FLIGHT, THE NR 1 ENG ACCESSORY GEARBOX CHIP DETECTOR LIGHT ILLUMINATED. DIVERTED WITHOUT INCIDENT.Apr 10, 2014 · N725JH · Skrsky S61N · Accessory GearboxesSDR 39LA2014031866Fire Loop · chafedON LANDING, TAXI AT OAIX THE NR 1 ENG FIRE WARNING LIGHT ILLUMINATED. INSTALLED FWD FIRE LOOP OPERATIONS CHECKED GOOD IAW S-61 MM CH 26.Mar 18, 2014 · N408UD · Skrsky S61N · Fire DetectionSDR 39LA2014031765Wire · shortedDURING CRUISE FLIGHT APPROXIMATELY 15 NM FROM OASD THERE WAS A LOUD POP & BANG FROM THE RT SIDE OF THE CB PANEL FOLLOWED BY SMOKE & AN ELEC SMELL. THERE WAS A LOSS OF AFCS, NR 2 FUEL BOOST PUMPS, & THE RECTIFIER. THE EMERGENCY CHECKLIST WAS PERFORMED & ALL NMar 17, 2014 · N261F · Skrsky S61N · Electrical Power System WiringSDR 39LA2014031364Warning Light · activatedDURING CRUISE FLIGHT THE NR 1 ENG FIRE WARNING LIGHT ILLUMINATED. THE EMERGENCY CHECKLIST WAS ACCOMPLISHED & THE DECISION WAS MADE TO DIVERT TO FOB WHICH WAS APPROXIMATELY 2 MILES AWAY. THE LANDING AT FOB WAS WITHOUT INCIDENT.Mar 13, 2014 · N408UD · Skrsky S61N · Fire DetectionSDR 39LA2014031263Fire Loop · chafedDURING CRUISE FLIGHT FROM OAIX TO OASH THE NR 1 ENG FIRE WARNING LIGHT ILLUMINATED. THE EMERGENCY CHECKLIST WAS ACCOMPLISHED & A RETURN TO OAIX WAS ACCOMPLISHED WITHOUT INCIDENT. FOUND FIRE LOOP CHAFFING ENG DECK, REPOSITIONED LOOP ACCOMPLISHED IAW S61N MM Mar 12, 2014 · N408UD · Skrsky S61N · Fire DetectionSDR CA140221024Sleeve · worn(CAN) ON GEAR BOX INSTALLATION, THE FEMALE THREADS GAVE WAY AS LUBE FITTING WAS TIGHTENED. ACFT HAS DEVELOPED AN OPTIONAL REPLACEMENT PART WITH A STEEL INSERT TO PREVENT SUCH OCCURRENCE FROM HAPPENING, REF SB 61B35-50.Feb 12, 2014 · Skrsky S61N · Main Rotor GearboxSDR 39LA2014021257Generator · failedAFTER DEPARTURE FROM OASH THE DC GEN LIGHT ILLUMINATED. ACCOMPLISHED THE EMERGENCY PROCEDURES, GEN WOULD NOT RESET. R & R DC GEN PN 30E20-97A IAW S61 MM 4045-80, REV 47, 24-20-01.Feb 12, 2014 · N103WF · Skrsky S61N · DC Generator-AlternatorSDR CA140218005Hose · failed(CAN) PRIMARY HYDRAULIC PRESSURE FLUCTUATING, AND LOW PRESSURE WARNING LIGHT ILLUMINATED IN FLIGHT. PRESSURE HOSE FROM PRIMARY HYDRAULIC PUMP TO MANIFOLD LEAKING AT MIDPOINT OF HOSE. NO INDICATION OF CHAFING OR ANOMALIES THAT MIGHT HAVE CAUSED THE HOSE TO FAFeb 11, 2014 · Skrsky S61N · Hydraulic System, MainSDR 39LA2014021158Window · departedAFTER DEPARTURE FROM OASH THE RT HAND EMERGENCY EXIT WINDOW DEPARTED THE AIRCRAFT. RETURNED TO OASH WITHOUT INCIDENT. INSTALLED SERVICEABLE EMERGENCY EXIT WINDOW IAW S61N MM SA-4045-83 CH 56-20-00.Feb 11, 2014 · N725JH · Skrsky S61N · Emergency ExitsSDR 39LA2014013056Brake Sys · contaminatedDURING TAXI THE BRAKES BECAME STUCK DURING FWD MOTION, THEN WOULD NOT STOP THE AIRCRAFT WHEN DEPRESSED. BLED MLG BRAKES IAW S61N MM 4045-80 REV 47 CHAPT 32-43-0, OPERATIONS CHECKED OKJan 30, 2014 · N616CK · Skrsky S61N · Landing Gear Brake SystemSDR 39LA2014012254Generator · failedAFTER DEPARTING OAIX DURING CRUISE FLIGHT THE NR 1 FUEL BOOST PUMP LIGHT ILLUMINATED FOLLOWED BY AN AFCS FAILURE. SHORTLY AFTER THE TAIL TAKE-OFF LIGHT ILLUMINATED WITH A NR 1 GEN WARNING LIGHT. THE EMERGENCY PROCEDURE CHECKLIST WAS EXECUTED WITHOUT RESOLUTJan 22, 2014 · N408UD · Skrsky S61N · AC Generator-AlternatorSDR 39LA2014012053Relay · failedON APPROACH TO OAKN THE GEN FAIL WARNING LIGHT ILLUMINATED WITH A MASTER CAUTION WARNING. THE EMERGENCY PROCEDURE TO TRY & RESTORE POWER WAS ACCOMPLISHED WITH NO RESULT. WE LANDED AIRCRAFT WITHOUT INCIDENT. REMOVED REVERSE CURRENT RELAY PN A-700AW, SN AP98Jan 20, 2014 · N364HH · Skrsky S61N · DC Generating SystemSDR 39LA2013122643Blower Motor · seizedHEATER BLOWER MOTOR SEIZED IN FLIGHT EMITTING SMOKE. REMOVED BLOWER MOTOR ASSEMBLY PN ME-600-1000, SN 1013 & INSTALLED OVERHAULED BLOWER MOTOR ASSEMBLY, FAN AXIVAN PN 500702-4491, SN AA-79463 IAW S-61MM SA4045-80, REV 47 CHAPTER 21 AIR CONDITIONING.Dec 26, 2013 · N408HH · Skrsky S61N · Heating SystemSDR 39LA2013121329Blower · failedDURING FLIGHT AT CRUISE ALTITUDE WITH CABIN HEAT ON, SMOKE WAS NOTICED COMING FROM THE HEATER AREA. REMOVED HEATER BLOWER PN ME-600-1000, SN 1632. INSTALLED SERVICEABLE HEATER BLOWER PN 500702-4491, SN AA6117 IAW SA4045-80, CH 21-40-0.Dec 13, 2013 · N612RM · Skrsky S61N · Heating SystemSDR 39LA2013121228Bearing · damagedDURING LANDING CREW FELT VIBRATION & ON SHORT FINAL MASTER CAUTION LIGHT ILLUMINATED WITH CORRESPONDING INTERMEDIATE GEARBOX CHIP DETECTOR LIGHT. REMOVED INTERMEDIATE GEARBOX PN S6135-66300-002, SN A15-887 & INSTALLED PN S6135-66300-2, SN A15-1045 IAW S-61 MMDec 12, 2013 · N116AZ · Skrsky S61N · Tail Rotor GearboxSDR 39LA2013120727Cable Assy · damagedNR 1 ENG FIRE WARNING LIGHT ILLUMINATED IN FLIGHT. TROUBLE SHOT SYS, FOUND DAMAGED LEAD, REPLACED WITH SERVICEABLE LEAD PN 35302-62, SN NA, WORK PERFORMED IAW S61N MM SA4045-80, CHP 26-00-00, OPERATIONS CHECKED GOOD 12/07/13.Dec 7, 2013 · N9119S · Skrsky S61N · Fire Protection System WiringSDR 39LA2013120226Door · openDURING TAKEOFF FROM FOB SHANK THE PASSENGER AIRSTAIR DOOR OPENED. THE TAKEOFF WAS ABORTED & AIRCRAFT RETURNED TO PARKING.Dec 2, 2013 · N408RC · Skrsky S61N · Passenger/Crew DoorsSDR 39LA2013111415Indicator · failedDURING CRUISE FLIGHT, ENROUTE, THE AFT FUEL CELL LOW LIGHT ILLUMINATED. TRANSFERRED KNOWN QUANTITY OF FUEL INTO AFT FUEL CELL WITH NO RISE IN AFT TANK INDICATION. ACFT DIVERTED WITHOUT INCIDENT. R & R AFT FUEL CELL INDICATOR GAUGE AND CALIBRATED TO AFT TANKNov 14, 2013 · N612RM · Skrsky S61N · Fuel Quantity IndicatorSDR 39LA201311066Connector · dirtyNR 2 ENGINE FIRE LIGHT INTERMITTENTLY ILLUMINATED IN FLIGHT. DISCONNECTED NR 2 ENG FIRE LOOP CONNECTORS, CLEANED AND CONNECTED FIRE LOOP CONNECTORS IAW MM 26-10 AS APPLICABLE. OPS CHECKED GOOD, LIGHT NO LONGER ILLUMINATED.Nov 6, 2013 · N364FH · Skrsky S61N · Fire Protection System WiringSDR CA131105014Blades · wrong part(CAN) THE ENGINE WAS SENT TO THE SHOP FOR SCHEDULED O/H. AFTER DISASSEMBLY, INSPECTION INDICATES THAT THERE WERE A NR OF STAGE 1, 3, 4, AND 9 COMPRESSOR BLADES THAT DO NOT CONFORM, AS THEY DID NOT HAVE THE CODE NR STAMPED INTO THE ROOT END AS IS STANDARD FOR Nov 5, 2013 · Skrsky S61N · Turbine Engine Compressor SectionSDR 39LA201311045Blanking Plate · departedAFTER DEPARTURE, ENROUTE, A WINDOW PLUG DEPARTED THE ACFT FROM THE LT EMERGENCY EXIT DOOR. AFTER LANDING IT WAS DISCOVERED THAT A TAIL ROTOR BLADE HAD BEEN DAMAGED AS A RESULT OF THE INCIDENT.Nov 4, 2013 · N803AR · Skrsky S61N · Emergency ExitsSDR 39LA201310314Generator · failedAFTER NR 2 ENGINE START CREW REPORTED STRANGE ODOR AND SMOKE IN THE CABIN. ENGINE SHUTDOWN WAS ACCOMPLISHED. REMOVED NR 2 AC GENERATOR, INSTALLED OVERHAULED NR 2 AC GENERATOR WORK PERFORMED IAW MM SA4045-80, CHSP 24-00-00 & 65.00.00 AS APPLICABLE, OPS CHECOct 31, 2013 · N9119S · Skrsky S61N · AC Generator-AlternatorSDR 39LA201310283Fire Loop · failedDURING CRUISE FLIGHT NR 2, ENGINE FIRE WARNING ILLUMINATED. R & R NR 2 ENGINE FIRE LOOP IAW MM CH26-10-3.Oct 28, 2013 · N116AZ · Skrsky S61N · Fire DetectionSDR 39LA201310182Fan · failedWHILE IN CRUISE, BOTH PILOTS NOTICED SMOKE COMING INTO THE COCKPIT FROM VENTS. BEGAN EMERGENCY CHECKLIST, THE SMOKE SOURCE WAS ISOLATED TO THE HEATER BLOWER MOTOR AND WAS SECURED. REMOVED FAN BLOWER, PN ME-630-10001-10, SN 1037, INSTALLED OVERHAULED FAN BLOWEOct 18, 2013 · N116AZ · Skrsky S61N · Air Distribution FanSDR 39LA2013101400004Window · departedCARGO DOOR WINDOW DEPARTED THE ACFT IN FLIGHT.Oct 9, 2013 · N116AZ · Skrsky S61N · Door WindowsSDR 39LA2013100400004Line · burstNR 2 ENGINE FLAMED OUT DURING TAKEOFF. R & R FUEL LINE FROM STATIC FILTER TO FUEL FLOW DIVIDER. PRIMED SYS LEAKED CHECKED, NO LEAKS NOTED.Oct 3, 2013 · N408UD · Skrsky S61N · Engine Fuel DistributionSDR 39LA2013090300004Engine · malfunctionedSUSPECTED COMPRESSOR STALL ON NR 1 ENGINE DURING CLIMBOUT. COMPLETED NR 1 ENG COMPRESSOR WASH AND INSPECTED FRONT FRAME. NO DAMAGE NOTED WORK DONE IAW SEI -182, CHAPTER 72-00, DATE 8/27/13.Aug 27, 2013 · N612RM · Skrsky S61N · Engine (Turbine/Turboprop)SDR 39LA2013082000004Compressor · stalledAT HOVER, MULTIPLE COMPRESSOR STALLS.Aug 19, 2013 · N725JH · Skrsky S61N · Turbine Engine Compressor SectionSDR 39LA2013080200004Fuel Filter · warning lightAFT FUEL FILTER BYPASS LIGHT ILLUMINATED IN FLIGHT. EXECUTED EMERGENCY CHECKLIST PROCEDURES AND LANDED. REPLACED FWD AND AFT AIRFRAME FUEL FILTERS IAW S61N MM REV47, CH28-00, LEAK CHECK PREFORMED, NO LEAKS FOUND,Aug 1, 2013 · N408WC · Skrsky S61N · Aircraft Fuel Filter/StrainerSDR 39LA2013062700004Fire Detector · false activationINTERMITTENT FIRE LIGHT ILLUMINATES, NR 1 ENGINE WITH NO EVIDENCE OF FIRE. INSPECTED NR 1 ENGINE FIRE DETECTOR SENSING ELEMENTS IAW MM 26-10-2. NO DEFECTS NOTED. REPOSITIONED FIRE DETECTOR SENSING ELEMENT IAW MM 26-10-2, PAR 1. PERFORMED MOC, NO DEFECTS Jun 26, 2013 · N616CK · Skrsky S61N · Fire DetectionSDR 39LA2013052900004Brake Sys · malfunctionedDURING TAXI, PILOT LOST PRESSURE IN RT BRAKE PEDAL MASTER CYCLINDER AND TEMP ODOR CAME FROM WHEEL ASSY. R & R BOTH INBD AND OTBD BRAKE DISC. R & R ALL FOUR BRAKES, BLED SYS. ALL WORK DONE IAW MM SA4045-80, REV 47, 32-43-0.May 27, 2013 · N803AR · Skrsky S61N · Landing Gear Brake SystemSDR CA130527005Purifier · chafed(CAN) ENGINE NR 2 WAS REMOVED FROM THE ACFT FOR A ROUTINE FUEL CONTROL & FUEL PUMP REPLACEMENT, DUE O/H. AT THIS TIME THE CFP WAS INSPECTED AND FOUND TO HAVE AN INTERNAL RUB BETWEEN THE CENTRIFUGE ASSY AND THE DRIVE HSG. METALLIC PARTICLES WERE ALSO FOUND INMay 25, 2013 · Skrsky S61N · Aircraft Fuel SystemSDR CA130516005Fcu · contaminated(CAN) METAL WAS FOUND IN THE FCU FILTER. UPON INSPECTION OF THE CFP EXTENSIVE RUBBING WAS FOUND. THIS CFP HAD ONLY BEEN INSTALLED FOR 26.7 HRS.May 9, 2013 · Skrsky S61N · Fuel Control/Turbine EnginesSDR 39LA2013032900004Unknown · smokeWHILE IN FLIGHT, COCKPIT FILLED WITH SMOKE FROM RT SIDE. INVERTER CAUTION WARNING LIGHT ILLUMINATED. PERFORMED CHECKLIST ITEMS FOR ELECTRICAL FIRE IN-FLIGHT AND LANDED.Mar 27, 2013 · N408FS · Skrsky S61N · Air Distribution SystemSDR 39LA2013031300004Hose · collapsedAFTER DEPARTURE, FUEL LOAD WAS 2800 LBS, T/O GW 17,594, TEMP 12 DEG MAGW 20,000, CG 265.2. WHEN A POWER CHANGE WAS MADE THE NR 1 ENGINE TORQUE OSCILLATED 30 TO 40 PERCENT, FUEL PRESSURE OSCILLATING 10 TO 15 PSI, AND T5 TEMPS OSCILLATING 30 TO 40 DEGREES. NF AMar 12, 2013 · N905AL · Skrsky S61N · Aircraft Fuel Distribution SystemSDR 39LA2013030800004Engine · malfunctionedIMMEDIATLY AFTER TAKEOFF AT APPROX 97 PERCENT NG THE NR 1 NG BEGAN TO FLUCTUATE 3-4 PERCENT. NOTICED THE NR 1 NF BEGIN TO FLUCTUATE AS WELL NR 1 FUEL PRESSURE AND T5. ALL INDICATIONS ON NR 2 ENGINE WERE NORMAL. APPROXIMATE 40 PERCENT TORQUE SPLIT WAS NOTED Mar 5, 2013 · N905AL · Skrsky S61N · Engine (Turbine/Turboprop)SDR 39LA2013022800003Gyro · unserviceableON CLIMBOUT, CREW EXPERIENCED RT ROLL AND OFF FLAG IN THE COPILOT'S ATTITUDE INDICATOR TWICE DURING FLIGHT, RESULTING IN AUTOMATIC FLIGHT CONTROL SYSTEM (AFCS) KICKING OFF LINE. PILOT ELECTED TO DECLARE AN EMERGENCY AND DIVERT. R & R P/R GYRO. OPS CHECKED GFeb 28, 2013 · N9119S · Skrsky S61N · Flight Environment DataSDR 39LA2013020400004Door · unsecureDURING DEPARTURE IN A 20KT LT TURN (LESS THAN 10 DEGREE AOB) THE AIR STAIR DOOR OPENED. PRIOR TO DEPARTURE THE CREW CHIEF SHUT AND LATCHED THE DOOR AND THE COCKPIT INDICATION CONFIRMED THE DOOR WAS CLOSED. IMMEDIATELY SLOWED ACFT DOWN TO 10KTS INDICATED TO EFeb 1, 2013 · N408RC · Skrsky S61N · Entrance StairsSDR 39LA2013012500003Access Panel · looseDURING CLIMB OUT, CREW CHIEF HEARD A CLAPPING NOISE FROM OUTSIDE THE ACFT. SUSPECTED THAT A PANEL WAS LOOSE AND SLAPPING AGAINST THE ACFT. SLOWED THE ACFT DOWN TILL THE NOISE STOPPED AND CONTINUED LANDING AT OUR NEXT STOP. AFTER LANDING CREW CHIEF DID A VISJan 25, 2013 · N103WF · Skrsky S61N · Fuselage Miscellaneous StructureSDR 39LA200401240003Pitch Control · unserviceableENROUTE, IN CRUISE FLIGHT THERE WAS A SUDDEN AND INADVERTENT PITCH UP AND ROLL OF ACFT, WHILE TRYING TO RECOVER UNUSUAL ATTITUDE ACFT PITCH AND ROLL CONTINUED INADVERTENTLY. THE CO-PILOTS VGI HAD NOT TUMBLED AT THAT POINT AND WAS INDICATING THE UNUSUAL ATTITUJan 24, 2013 · N803AR · Skrsky S61N · Autopilot SystemSDR 39LA2004012400003Pitch Control · unserviceableENROUTE, IN CRUISE FLIGHT, THERE WAS A SUDDEN AND INADVERTENT PITCH UP AND ROLL OF ACFT, WHILE TRYING TO RECOVER, UNUSUAL ATTITUDE ACFT PITCH AND ROLL CONTINUED INADVERTENTLY. THE CO-PILOTS VGI HAD NOT TUMBLED AT THAT POINT AND WAS INDICATING THE UNUSUAL ATTIJan 24, 2013 · N803AR · Skrsky S61N · Autopilot SystemSDR 39LA2013012400003Pitch Control · unserviceableENROUTE, DIVERTED, DUE TO SUSPECTED CONTROL ISSUE. REMOVED SUSPECTED MALFUNCTIONING COPILOT PITCH AND ROLL GYRO, PN 121672-01-17, SN 0000450. INSTALLED SERVICEABLE COPILOT PITCH AND ROLL GYRO, PN 121672-01-17, SN 0000507 IAW S61 MM CH 22-10-18, PG 201. OPS CJan 24, 2013 · N803AR · Skrsky S61N · Autopilot SystemSDR 39LA2013011500001Fuel Filter · blockedDEPARTED, CLIMBING TO 9,000' AFT FUEL FILTER BYPASS LIGHT ILLUMINATED. DIVERTED TO FOB FOR REPAIR. MONITORED FUEL PRESSURE ENTOUTE TO FOB. CHECKED EMERGENCY PROCEDURES IN CHECKLIST AND COMPLETED ITEMS. R & R FOWARD AND AFT FUEL FILTERS IAW S-61 MM, REV 47, CJan 15, 2013 · N116AZ · Skrsky S61N · Aircraft Fuel Filter/StrainerSDR 39LA2013011600004Filter · cloggedWHILE ENROUTE, AFTER DEPARTING, AFT FUEL FILTER BYPASS LIGHT ILLUMINATED. TURNED TOWARD DESTINATION AND VERIFIED EMERGENCY ACTIONS WITH CHECKLIST. FUEL PRESSURES REMAINED NORMAL FOR DURATION OF FLIGHT. FUEL LOW PRESSURE LIGHT DID NOT ILLUMINATE. LANDED FORJan 13, 2013 · N725JH · Skrsky S61N · Aircraft Fuel Distribution SystemSDR 39LA201301150023Chip Detector · contaminatedAT CRUISE ALTITUDE, THE NR 1 ENGINE CHIP LIGHT ILLUMINATED. A RESET WAS ATTEMPTED WITH NO AFFECT. ACFT DIVERTED FOR MX. MX REMOVED THE CHIP DETECTOR AND CLEANED IT. AFTER REINSTALLATION NO LIGHTS WERE INDICATED DURING OR AFTER RUN UP.Jan 7, 2013 · N61NH · Skrsky S61N · Turbine Engine Oil SystemSDR 39LA2013010600001Line · crackedHELICOPTER DEPARTED, ENROUTE, CREW CHIEF NOTICED THAT HYD FLUID WAS LEAKING FROM THE DRIP PAN UNDER THE TRANSMISSION. HELICOPTER DIVERTED. HYD LINE WAS FOUND TO HAVE A CRACK. HYD PRESSURE REMAINED NORMAL ON BOTH HYD SYSTEMS. FABRICATED HYD LINE IAW AC 43.13-Jan 6, 2013 · N612RM · Skrsky S61N · Hydraulic System, MainSDR P4YA2012121500001Blade · damagedAFTER TAKEOFF, NR 1 ENGINE LOST POWER, LOUD REPORT FROM ENGINE AND LANDED IMMEDIATELY. MX INSPECTED NR 1 ENGINE AND FOUND 1ST AND 2ND STAGE COMPRESSOR BLADE DAMAGE DUE TO FOD. R & R NR1 ENGINE.Dec 12, 2012 · N116AZ · Skrsky S61N · Turbine Engine Compressor SectionSDR P4YA2012102700001Fire Loop · pinchedNR 2 ENGINE FIRE WARNING LIGHT ILLUMINATED WHILE LANDING. FOUND FORWARD FLEXIBLE FIRE LOOP LINE PINCHED BETWEEN COWLING AND AIRFRAME. REPOSITIONED AND LIGHT WENT OUT. PERFORMED FIRE LIIP TEST AND FOUND OK.Oct 27, 2012 · N408WC · Skrsky S61N · Fire DetectionSDR P4YA2012102600001Unknown · odorWHILE IN FLIGHT, RECEIVED A WHINE IN HEADSET AND AN ODOR OF BURNING INSULATION, SECURED HEATER AND VENT SWITCHES. AFTER LANDING, REMOVED BAGS BLOCKING VENT. INSPECTED HEATER ASSY, NO SIGN OF BURNED WIRE OR DAMAGE, OPS CHECKED SYSTEM AND CHECKED GOOD.Oct 26, 2012 · N408WC · Skrsky S61N · Air Distribution System
Back to Sikorsky/Carson Services S61N