SDR 2004F00380Bellows · contaminatedON TAKEOFF, THE NR 1 ENGINE STARTED TO SURGE. MAINTENANCE REMOVED FUEL CONTROL, FOUND WATER IN THE P1 BELLOWS REMOVED WATER AND REINSTALLED FUEL CONTROL, OPS CHECK WAS GOOD. (M)SDR ERAA097512Float · leakingFLOAT LEAKING. SENT TO OFFSHORE HELICOPTER FOR REPAIR. REPAIRED IAW OHSS 100-1 AND C/W INSPECTION IAW 32-70-03.SDR ERAA097510Blade · erodedT/R BLADE HAS EROSION. SENT TO CTI FOR REPAIR. UNIT X-RAYED, ULTRASONIC INSPECTED PER QATI3016.3261 AND 3098 PERFORMED ALL SCHEDULED INSPECTIONS UP TO AND INCLUDING 1500 HOUR INSPECTION IN ACCORDANCE WITH COMPOSITE MM 4047-76-5 TABLE 3-2 AND MM 4047-76-2, 65SDR ALG2004F00034Connector · dirtyAFTER TAKEOFF AND ENTERING CRUISE FLIGHT THE NR 2 SERVO SYSTEM CAUTION LIGHT ILLUMINATED, AFTER UTILIZING EMERGENCY CHECKLIST WAS UNABLE TO EXTINGUISH LIGHT, LANDED AND REFERRED TO MAINTENANCE. MAINTENANCE CLEANED CONNECTORS ON THE NR 2 HYDRAULIC MODULE NO FUSDR HEEA096020Wire · burnedNR 2 ENGINE HAD RUNAWAY BEEP CAUSING A 30 PERCENT TORQUE SPLIT. RETARDED NR 2 THROTTLE TO 38 PERCENT TORQUE AND LANDED. MAINTENANCE FOUND THE WIRES FOR THE NR 2 NS BEEP MOTOR RUNNING BETWEEN CONNECTORS P314 AND P104 TO BE BURNED AND CHAFED AT FUSELAGE STATIOSDR HEEA096021Wire · damagedNR 2 ENGINE N2 BEEP UNCONTROLLABLE CAUSING 30 PERCENT TORQUE SPLIT. RETARDED NR 2 THROTTLE TO A SETTING OF 38 PERCENT AND LANDED. MAINTENANCE FOUND BAD WIRING IN THE COPILOT COLLECTIVE STICK. REWIRED THE COLLECTIVE STICK AND REPLACED THE GOVERNOR SWITCH.SDR CA040909006Bearing · spalled(CAN) DURING ROUTINE 3 YEAR INSPECTION OF THE MAIN ROTOR SWASHPLATE DUPLEX BEARING AME DISCOVERED ONE OF THE BALLS TO BE SEVERELY SPALLED, BEARING WAS REPLACED AND A/C RETURNED TO SERVICE. SUBSEQUENTLY THE OUTER RACE WAS CUT OPEN REVEALING NO OTHER DAMAGE TO SDR ALG2004F00033Smoke Detector · will not testDURING RUN UP, FIRE DETECTOR IN AFT BAGGAGE COMPARTMENT LIGHT FAILED TO COME ON DURING TEST. MAINTENANCE CARRIED FORWARD TO MCOD, PART IS ON ORDER AND IT IS A 10 MEL ITEM. A FOLLOW UP REPORT WILL BE TURNED IN WHEN THE PART IS CHANGED AND OPERATIONAL CHECK ISSDR AUS20040511Engine · making metal(AUS) ENGINE CHIP DETECTORS AND OIL FILTER CONTAMINATED WITH METAL. ENGINE WAS REPLACED.SDR HEEA095228Actuator · malfunctionedDURING CRUISE FLIGHT NR 2 ENGINE BEEPED TO MINIMUM BY ITSELF. BEEPED ENGINE BACK UP BUT ENGINE AUTO BEEPED TO MINIMUM. COMPLIED WITH EMERGENCY CHECK LIST AND LANDED AT NEW ORLEANS.SDR ERAA096623Tip Cap · debondedTIP CAP ASSY BOTTOM DISBONDED. SENT TO CTI FOR REPAIR. INSPECTED PER SA4047-76-5 REV11; REPAIRED KEVLAR PER PROCEDURE NR 2 AND NR 18 1 PLY; REFINISHED PER DRWG NO 76150-09043; STATIC BALANCE PER RS-005N-VI.SDR ALGA097672Gear · spalledFOUND SPALLING ON GEAR TEETH. RETURNED TO VENDOR FOR WARRANTY CREDIT.SDR ALGA094285Gear · spalledFOUND SPALLING AND GALLING ON PINION GEAR TEETH. SENT TO VENDOR FOR WARRANTY CREDIT.SDR ERAA096622Blade · peelingTRIM TAD PEALING/SEPARATED. INSPECTED, PERFORMED X RAY ULTRASONIC INSPECTIONS PER QATI 3048, 3016, SS8806 & 3095, PERFORMED ALL INSPECTIONS UP TO AND INCLUDING 900 HOUR INSPECTIONS, COMPLIED WITH AD 884-10-02 & ASB 76-65-18C; REPLACED TRIM TAB 1 ER PER RS-006SDR HEEA094159Seal · leakingNR 1 HYDRAULIC LIGHT ILLUMINATED DURING CRUISE FLIGHT FOLLOWED BY FLUCTUATING PRESSURE. SHUT DOWN NR 1 HYDRAULIC SYSTEM. MAINTENANCE FOUND NR 1 HYDRAULIC PUMP DRIVE SHAFT SEAL LEAKING AND NR 1 HYDRAULIC PUMP PRESSURE HOSE RUPTURED. REPLACED NR 1 HYDRAULIC PSDR ALGA093899Gear · spalledFOUND HEAVY SPALLING ACROSS GEAR TEETH OF PTO GEAR.SDR ALGA093898Bearing · spalledMAIN GEARBOX DISASSEMBLED FOR METAL CONTAMINATION, FOUND BEARING BREAKING DOWN.SDR ALG2004F00016Engine · overtempIN STRAIGHT AND LEVEL FLIGHT, NR 1 ENGINE OIL TEMPERATURE BEGAN TO CLIMB. AS IT APPROACHED, THE RED LINE WE BEGAN TO MONITOR CLOSELY. WHEN IT WENT ABOVE THE RED LINE, I FOLLOWED CKLIST PROCEDURES AND SHUT DOWN NR 1 ENGINE, MADE RUN ON LANDING. NO OTHER INDISDR AC2A094055Battery · swollenBATTERY SWELLED. REPLACED WITH SERVICEABLE WATER ACTIVATED LIFE ASSEMBLY.SDR HEEA094027Connector · corrodedWHILE IN CRUISE FLIGHT NR 2 ENGINE FIRE LIGHT ILLUMINATED. FOLLOWED EMERGENCY CHECK LIST FOR ENGINE FIRE LIGHT. RETURNED TO BASE. INSPECTED FOR SIGNS OF FIRE AND OR SMOKE, NONE FOUND. FOUND DEFECTIVE (CORRODED) CONNECTOR. REPLACED CONNECTOR.SDR HEEA093674Wire · brokenNR 2 ENGINE OIL TEMPERATURE STARTED FLUCTUATING. MAINTENANCE REPAIRED A BROKEN WIRE NEAR THE NR 2 ENGINE OIL TEMPERATURE BULB.SDR HEEA093675Amplifier · burnedSMELLED ELECTRICAL FUMES DURING FLIGHT. LANDED AT MP299B. MAINTENANCE FOUND YAW CHANNEL AMP BURNED.SDR ALGA097415Bearing · spalledTRANSMISSION DISASSEMBLED FOR METAL CONTAMINATION, FOUND ROLLER BEARING BREAKING DOWN. REMOVED AND REPLACED BEARING.SDR HEEA093676Engine · malfunctionedDURING CRUISE FLIGHT NR 2 ENGINE TORQUE DROPPED TO 10 PERCENT AND NR 1 ENGINE TORQUE ROSE TO 99 PERCENT. ROTOR RPM DECREASED TO 104 PERCENT. MAINTENANCE REPLACED THE NR 1 ENGINE ASSEMBLY.SDR ALG2004F00004Amplifier · inoperativeFIRE WARNING LIGHT ON NR 2 ENGINE ILLUMINATED. NO FIRE WAS SEEN. MAINTENANCE REMOVED AND REPLACED FIRE DETECTOR CONTROL AMP.SDR HEEA093673Oil Cooler · crackedIN CRUISE FLIGHT, THE NR 2 ENGINE OIL TEMPERATURE ROSE TO THE RED LINE. SECURED ENGINE AND LANDED WITHOUT INCIDENT. MAINTENANCE FOUND THE AFT JUNCTION OF THE OIL COOLER BLOWER DUCT CRACKED AND SPLIT OPEN.SDR HEEA093480Fuel Control · failedNR 2 ENGINE HIGH SIDE FAILURE. MAINTENANCE REPLACED FUEL CONTROL.SDR ERAA095249Blade · corrodedTHIS INFO FOR FAA SDR. BLADE ASSY HAS CORROSION AT C BLOCK TO SPAR BOUND LINE. ACTION TAKEN: SENT TO CTI FOR REPAIR. INSPECTED, PERFORMED X- RAY FOR MOISTURE (FOUND APPROX 50-60 CELLS IN VIEW, E-9) REPLACED C BLOCK PER RS-008G-11, REPLACED SHIMS PER SA404SDR HEEA093481Pressure Switch · inoperativeIB TO GRAND ISLE THE NR 1 SERVO CAUTION LIGHT ILLUMINATED. LANDED WITHOUT INCIDENT.SDR HEEA093483Engine · failedWHILE IN CRUISE FLIGHT HEARD A BUMP, THE AIRCRAFT YAWED, NR 1 ENGINE OUT LIGHT CAME ON, MAST CAUTION LIGHT CAME ON, ENGINE CHIP LIGHT CAME ON, AND ALL GAUGES WENT TO ZERO ON THE NR 1 ENGINE. CONTINUED FLIGHT AND LANDED AT AIRPORT.SDR AC2A092345Windshield · crackedWINDSHIELD IS CRACKED ON RIGHT HAND SIDE OF WINDSHIELD. CRACK RUNS INBOARD TOWARD CENTER OF WINDSHIELD FROM RIGHT HAND SIDE. WE HAVE EXPERIENCED SIMILAR CRACKING IN THESE WINDSHIELDS BEFORE. THE MECHANICS INVOLVED THINK THIS CRACKING IS DUE TO THE STRESSES CRESDR AC2A093322Servo · brokenPILOT VALVE INPUT ROD TURN BARREL HAD BROKEN RETAINING BOLT. THIS ENABLED THE BARREL TO TURN WHICH COULD ALTER THE SERVO TIMING. REPLACED MAIN ROTOR ASSEMBLY.SDR ALG2004F00000Engine · making metalIN FLIGHT, NR 2 ENGINE CHIP LIGHT CAME ON. MAINTENANCE FOUND METAL ON FWD PLUG ON NR 2 ENGINE. SMALL RING OF TINY FLAKES ON OUTSIDE PERIMETER OF CHIP PLUG. AIRCRAFT AOG FOR ENGINE.SDR HEEA092085Fuel Control · failedNR 2 ENGINE HAD HIGH SIDE GOVERNOR FAILURE. MAINTENANCE REPLACED THE FUEL CONTROL UNIT.SDR HEEA092087Relay · failedNR 2 GENERATOR FAILED IN FLIGHT. (DC CONTROL P/N 51530-006B, S/N 10799B) MAINTENANCE REPLACED NR 2 GENERATOR CONTROL RELAY AND ALSO NR 1 GENERATOR DC CONTROL UNIT.SDR ALGA091288Pinion Gear · spalledFOUND SPALLING ON PINION GEAR TEETH. SENT PART TO VENDOR FOR WARRANTY CREDIT.SDR ERAA093709Tip Cap · crackedABRASION STRIP CRACKED AND DEBONDED ON UPPER SURFACE AS INDICATED C-CHANNEL DEBONDED AS INDICATED. ACTION TAKEN: SENT FOR REPAIR. INSPECTED IAW SA 4047-76-5 REV 11; REPLACED ABRASION STRIP IAW RS-005N-III. MODIFIED EXTERNAL DOUBLERS IAW RS-017-1; INSTALLED SDR ERAA093708Cap · crackedLEADING EDGE ABRASION STRIP AND UPPER OUTER DOUBLER CRACKED. C-CHANNEL DEBONDED AND DAMAGED AS INDICATED. SENT TO FOR REPAIR. INSPECTED IAW SA4047-76-5 REV11; REPLACED ABRASION STRIP IAW RS-005N-III, MODIFIED EXTERNAL DOUBLERS IAW RS-017. INSTALLED STAINSDR ERAA091803Fire Bottle · misrepairedFIRE BOTTLE NEEDS TO BE SERVICED. INCORRECT GAUGE INSTALLED. HYDRO TESTED, OVERHAULED, INSTALLED GAUGE, FILLED, LEA AND WEIGHT CHECKED.SDR CA031120008Duct · separated(CAN) DURING NORMAL DAILY TREND CHECK, PILOT NOTICED GRADUAL INCREASE IN ENG OIL TEMP ON NR 2 AND REPORTED TO THE ENGINEER. INSPECTION CARRIED OUT ON THE NR 2 OIL COOLER DUCT INSTALLATION IN WHICH THE FLEXIBLE DUCT LOCATED BELOW THE BLOWER ON THE INSIDE OF THSDR ALG2003F00104Pump · failedAIRCRAFT RUNNING ON THE PLATFORM. THE NR 2 HYDRAULIC FAILED WHILE THE AIRCRAFT WAS ON THE PLATFORM, MAINTENANCE WAS NOTIFIED. THE MECHANIC REMOVED AND REPLACED THE NR 2 HYDRAULIC PUMP DUE TO A SHEERED SHAFT, GROUND RUN WAS PERFORMED AND AIRCRAFT WAS RETURNEDSDR ALG2003F00101Relay · failedON PRE-FLIGHT, THE FIRE EXTINGUISHER SYSTEM FAILED. MAINTENANCE WAS INFORMED AND THE MECHANIC REMOVED AND REPLACED THE K2 RELAY IN THE NR 1 RELAY IN THE OVERHEAD PANEL IAW MM. THE AIRCRAFT WAS RETURNED TO SERVICE.(K)SDR ERAA093710Blade · damagedPOLYURETHANE STRIP ERODED BOTH BLADES, TRAILING EDGE TAB DAMAGED. EROSION NEAR TIP. SENT FOR REPAIR. X RAYED ULTRASONIC INSPECTED IAW QATI 3016 AND 3098, PERFORMED ALL SCHEDULED INSPECTIONS UOP TO AND INCLUDING 1500 HR INSP IAW COMPOSITE MATERIALS MANUAL 4SDR HEEA090146Wire Harness · damagedDURING APPROACH, DID NOT GET A GREEN LIGHT FOR NOSE GEAR. ABORTED LANDING. LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED DOWN LOCK HARNESS.SDR ALG2003F00102Wire · shortedIN CRUISE FLIGHT, SMELLED SMOKE AND SAW SMOKE FLOWING OUT OF OVERHEAD QUADRANT FRONT BY FIRE HANDLES. EXECUTED TURN AROUND TO INTRACOASTAL AND SMOKE STOPPED. FIRE EXTINGUISHER CIRCUIT BREAKERS POPPED. RETURNED TO INTRACOASTAL, EVERYTHING ELSE NORMAL INDICATSDR CA031010002Labyrinth Seal · failed(CAN) SEVERAL CHIP LIGHTS WERE EXPERIENCED DURING OPERATION WHICH PROMPTED THE REMOVALOF ENGINE. MAGNETIC PARTICLES WERE NOTED ON THE UPPER GEARBOX CHIP DETECTOR. UPON FLUSHING THE TURBINE NR 8 BEARING AREA FERROUS PARTICLES AND SILVER FLAKES WERE FOUND. UPON SDR HEEA090149Contactor · failedAFTER ENGINE START AND PRIOR TO TAKE OFF, BATTERY OFF CAUTION LIGHT ILLUMINATED AND WOULD NOT GO OUT. MAINTENANCE REPLACED BATTERY RELAY.SDR CA030918012Generator · out of adjust(CAN) DURING TRAINING, INFLIGHT ENGINE SHUTDOWN AND RESTART PROCEDURES WERE BEING DEMONSTRATED. WHEN START WAS ATTEMPTED THE THE OVERSPEED SYSTEM TRIPPED AND PREVENTED THE RESTART. TROUBLESHOOTING INDICATES THAT A OUTPUT VOLTAGE OF 28.55 VDC FROM THE OPERATINGSDR ALG2003F00072Squat Switch · malfunctionedDURING TAKE OFF PHASE, THE LANDING GEAR WOULD NOT RETRACT, RETURNED TO ARA FOR MAINTENANCE. MAINTENANCE ADJUSTED WEIGHT ON WHEEL SWITCH IAW S76 MM.SDR ALG2003F00095Chip Detector · contaminatedON CLIMB OUT, ON MISSED APPROACH OFF ILS LAKE CHARLES, NR 2 ENGINE CHIP LIGHT ILLUMINATED, THE PILOT FOLLOWED EMERGENCY PORCEDURE CHECKLIST AND THE LANDING WAS UNEVENTFUL AND NOTIFIED MAINTENANCE. THE MECHANIC REMOVED THE NR 2 ENGINE LOWER FORWARD GEARBOX CHI
Back to Sikorsky S-76A