DURING CLIMB AT 1400 FT, ENG 1 STRUT OVERHEAT LIGHT ILLUM. ACCOMPLISH ON RED TAB PROC. SECURED LOOSE CLAMP AT FWD DUCT OF NR 1 ENG PLYON PRECOOLER. RAN ENG, OP CK OK PER MM 26-14-001-2.