Service difficulty report · Terminal Block · Doug DC1010

Difficulty date
August 22, 2000
Submitted
August 24, 2000
Operation
Air carrier
Aircraft
N371FE
Make and model
Doug DC1010
Aircraft serial
46609
Part
Terminal Block
Condition
Overheated
Location
Rt Windshield
Stage of operation
CR
How discovered
O
Nature of condition
B
Precautionary procedure
H

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ELECTRICAL FUMES IN FLT ISOLATED SOURCE FROM AC BUS 1 PULLED CB. REMOVED AND REPLACED TERMINAL BLOCK, FILTER AND CONTROLLER FOR RT WINDSHIELD PER DC10-10 MM CHAPTER 30-41-01-2 AND 30-41-03-4. CHECKS GOOD ON TEST. RESET NR 1 AC BUSS.

More about the Doug DC-10-10