What it covers
The system and components which is used to clear, eliminate or prevent the formation of rain, ice or Typical parts are motor, actuator, wiper blade, hydraulic converter, shaft, line, switch, the electrical heating portion of heated glass panels, control units, alcohol deice system lines, tanks, pumps, valves, etc.
Service difficulty reports · 3,394
Reports filed under 3040, newest first.
| 1995 | 43 |
|---|---|
| 1996 | 46 |
| 1997 | 46 |
| 1998 | 45 |
| 1999 | 32 |
| 2000 | 50 |
| 2001 | 86 |
| 2002 | 75 |
| 2003 | 55 |
| 2004 | 58 |
| 2005 | 54 |
| 2006 | 53 |
| 2007 | 92 |
| 2008 | 94 |
| 2009 | 58 |
| 2010 | 86 |
| 2011 | 133 |
| 2012 | 143 |
| 2013 | 147 |
| 2014 | 98 |
| 2015 | 136 |
| 2016 | 123 |
| 2017 | 179 |
| 2018 | 277 |
| 2019 | 275 |
| 2020 | 139 |
| 2021 | 163 |
| 2022 | 195 |
| 2023 | 219 |
| 2024 | 80 |
| 2025 | 53 |
| 2026 | 61 |
SDR IPXA2026101325515Heater · inoperativeFO`S R2 WINDOW HEAT INOP DEFERRED FO€™S SIDE WINDOW R2 IAW MEL 30-41-1-2. PLACARD INSTALLED, DMP C/W.SDR CALA2026100720205Warning Light · illuminatedWINDOW HEAT OVERHEAT LIGHT ON RT SIDE. FOUND NR 2 RIGHT SIDE WINDOW HEAT INOPERATIVE. MEL 3011K APPLIED. FO NOTED POSSIBLE ELECTRICAL ARCING ODOR PRIOR TO WINDOW HEAT LIGHT COMING ON. RAN BITE TEST OF WHCU SYS SEVERAL TIMES IN REF AMM 30-41 TASK 801. NOSDR AALA202610068916Motor · uncontrollableAIRCRAFT WAS GROUNDED: 30-65A WIN WIPER - UNCOMMANDED MOVEMENT OF LEFT WINDOW WIPER WHILE IN PARK DURING CLIMB OUT AT ABOUT 11000FT. AFTER TROUBLESHOOTING DECESION MADE TO DIVERT TO CLT TO SWITCH AIRCRAFT AN EMERGENCY WAS DECLARED AND AIRCRAFT LANDED WITHOUT I