As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RED NOSE GEAR WARN LIGHT ILLUM. RECYCLED GEAR LIGHT GREEN ON 2ND ATTEMPT. INSP DOWN PROX AND LOCK PROX SENSOR FOUND NORMAL. PROX SWITCH ELECTRONICS UNIT. TEST PASSED NO SIGNS OF LEAKAGE OR DAMAGE ON UNLOCK CYLINDER AND CK VALVE PER FIM 32-30-06-02. AC OK FOR SERVICE.