What was found
CORROSION ON LOWER CHORD BS 1070 FLOORBEAM LBL 45, RBL 50, WL 200. REMOVED AND REPLACED FLOORBEAM PER SRM 51-30-2, 53-10-1 FIG 4 & 53-10-8 FIG 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON LOWER CHORD BS 1070 FLOORBEAM LBL 45, RBL 50, WL 200. REMOVED AND REPLACED FLOORBEAM PER SRM 51-30-2, 53-10-1 FIG 4 & 53-10-8 FIG 2.