What was found
AT MOBILE AEROSPACE ENGINEERING (VENDOR) BFM FOUND DURING C-CHECK INSPECTION THE NR 7 SLAT EXTEND CABLE LT WING, UNRAVELED, ALL STRANDS BROKEN EXCEPT FOR ONE. REMOVED AND REPLACED NR 7 SLAT EXTEND CABLE. TENSIONED LT NR 7 SLAT AND EXTEND RETRACT CABLE, AND OPS CHECKED GOOD, ALL IAW MM 27-80-00-5.