What was found
AFTER RETRACTING FLAPS TO 2 THE RED L/E ANNUNCIATOR LIGHT REMAINED ILLUMINATED. POSITION TEST SHOWED NR 2 L/E FLAP INTRANSIT. RED TABS COMPLETED AND LIGHT WENT OUT, AFTER 1 MIN RED L/E FLAPS LIGHT ILLUMINATED AGAIN (WITH FLAPS IN THE UP POSITION). RED TABS REINITIATED AND A/C RETURNED TO MEM. TROUBLESHOT THE 2 WIRES AND ASSOCIATED COMPONENTS BETWEEN C/P AT FLAP 2 POS SW, S203, AND LEADING EDGE FLAP POS TEST MODULE, M119, W/MULTIMETER. ALL RINGS NORMAL AND NOT SHORTED TO GND. REF FX727 WDM 27-81-01 AND 27-81-02. REMOVED AND REPLACED WORN BUSHING ON THE NR 2 L/E FLAP SWITCH LINKAGE PER AMM 27-82-001-4. OPS CHECK NORMAL, NO ADJUSTMENT NECESSARY.