What was found
LOWER AFT BODY HEAT LIGHT ILLUMINATED, FOLLOWED RED TAB PROCEDURES AND LIGHT EXTINGUISHED. LIGHT ILLUMINATED DURING CLIMB EPR AT 205. PER RED TAB ISOLATION PRODEDURE FAULT OCCURRED IN NR 3 ENG - RH PACK PNEU DUCTING. INSPECTED AFT AIRSTAIR AREA O/H LOOP AND FOUND LOOP TOUCHING IN TWO PLACES. REPOSITIONED AS NECESSARY. RAN ENGINE TO 2.00 EPR AND FAULT DID NOT RE-OCCUR. FOR PRECAUTION CHECKED INTEGRITY AND OPERATION OF RH PNEU SYSTEM PER JRH 7- 19. CKS OK. CHECKED AFT CARGO COMPT AND KEEL BEAM AREA FOR WARM AREA'S CKS OK. DUCT PNEUMATIC PRESS ALL CKS OK. PERFORMED TROUBLESHOOTING CK PER MM 26-14- 000-1 AND OPS CK AS PER MM 26-14-000-5. CKS NORMAL.