What was found
RIGHT HORIZONTAL UPPER TRAILING EDGE SPAR I/B OF RIB 5 HAS LEVEL 2 CORROSION, APPROX 6 INCHES L X .800 INCH W, NOTE: PREVIOUS STRAP REPAIR INSTALLED I/B OF DAMAGE TO RIB 3. REMOVED PREVIOUS REPAIR, REMOVED CORROSION, MAT'L LOSS GREATER THAN 10 PERCENT, FABRICATED NEW REPAIR ANGLE. INSTALLED NEW REPAIR ANGLE AND TREATED, PRIMED AND APPLIED TOP COATING IAW A310 SRM 55-11-21, 51-23-20, AND 51-74-10.