What was found
RT AFT (FLAP SIDE) I/B FLAP O/B HINGE, O/B PIVOT BORE SPOTFACE CORRODED. RT AFT (FLAP SIDE) I/B FLAP O/B HINGE, O/B PIVOT BORE SPOTFACE CORROSION REMOVED AND REPAIRED AS PER CMM 57-52-03 PAGES 442-443. ORIGINAL THICKNESS=0.652 INCH, REMAINING THICKNESS=0.585 INCH, MATERIAL REMOVED=0.067 INCH, AND FOUND WITHIN LIMIT AS PER CMM 57-52-03.