What was found
RT FWD (WING SIDE) O/B FLAP I/B HINGE, LOWER MOUNT SPOTFACE CORRODED. RT FWD (WING SIDE) O/B FLAP I/B HINGE, LOWER MOUNT SPOTFACE CORROSION REMOVED AND EXCEED LIMITS PER CMM 57-44-08, ORIGINAL THICKNESS = 0.500 INCH, MATERIAL REMOVED = 0.012 INCH, REMAINING THICKNESS = 0.488 INCH FOUND WITHIN TOLERANCE OF DWG ARC0502.