What was found
AT APPROXIMATELY 11 0`CLOCK POSITION 14 4/5 INCHED FROM RIGHT HAND PRIMARY STATIC PORT, THE SKIN IS DIMPLED APPROXIMATELY .022 INCHES. REWORKED DENT IAW MD10 SRM 53-20-00 VOL I, PERFORMED HFEC IAW NDT MANUAL SPM 06-10-10 .001. NO CRACKS FOUND. DENT WITHIN LIMITS IAW MD10-10 MM 34-11-01-2. PERFORMED RVSM INSPECTION OF THE NOTED DISCREPANT AREA, MEASUREMENT -0.001, FOUND TO BE WITHIN LIMITS IAW MD10-10 MM 34-11-01-2. REF. N/R N00228.