What was found
LEFT WING OUTBOARD FLAP INBOARD HINGE, LOCATION NR 4 BORE CORRODED. REMOVED CORROSION IAW DACCMM 57-44-08, INSPECTED IAW DACCMM 57-44-08 AND 20-11-02. PEENED IAW DACCMM 57-44-08 AND 20-11-01. PRIMED IAW DC10 SRM 51-21-01 VOL. II. FABBED BUSHING IAW DACCMM 57-44-08 AND EA 8-5750-81470. CAD PLATED BUSHING IAW DACCMM 57-44-08 AND 20-10-01. INSTALLED AND HONED BUSHING IAW DACCMM 57-44-08. BEGINNING BORE 2.300 INCH FINAL BORE 2.3414 INCH MATERIAL REMOVED .0414 INCH IAW DACCMM 57-44-08.