What was found
DURING CLIMB THROUGH 17,000 FT, NOTICED NR 1 ENG OIL PRESS AT 27 PSI. SHUT ENG DOWN IAW RED TABS LANDED IN MEM. ENT BY: 206208 RPT BY: 111069, SWAPED NR 1 AND NR 2 OIL PRES IND, RAN NR 1 ENG OIL PRES IND STUCK AT 27PSI, LOP LIGHT WAS OUT ALL OTHER IND WERE NORMAL, POSSIBLE OIL PRESS TRANSMITTER. REMOVED AND REPLACED PRESSURE TX REF PER MM 79-33-001-4. OPS CK AND LEAK CK NORMAL REF PER 79-32-000-5. RAN ENG PER JRH CH 5, ALL IND NORMAL.