What was found
CENTER LANDING GEAR, RT TRUNNION SUPPORT FITTING MATING SURFACE FOUND CORRODED AND EXCEED LIMIT AREA OF 10 PERCENT PER SRM 53-40-00 FIGURE 15, SHEET 4. (FOR LOCAL BLEND OPTIONS) AEA7051-502. REPAIR CARRIED OUT IAW FEDEX EA 1-5340-82950.