What was found
FUSELAGE EXTERNAL SKIN, SECTION 48, BS 1329 LBL 22 3 INCHES O/B OF AFT AIRSTAIR CUTOUT GOUGED. *S/D* GOUGED IN EXTERNAL SKIN OF THE AFT AIRSTAIR CUTOUT AT BS 1329 LBL 22 WAS OUT OF LIMITS IAW SRM 53-30-1. CUT OUT DAMAGE AND FABRICATED REPAIR IAW SRM 51-10-2, ALODINE & PAINTED IAW FED EX 51-20-031-7. INSTALLED FASTENERS IAW SRM 53-30-2.