What was found
FWD CARGO COMPT FOUND CRACK 1 INCH LONG ON BEAM AT STA 6-70 STRINGER 42 RT SIDE. CUTTED DAMAGE AND INSTALL NEW SPLICE REPAIR IAW SRM 53-00-01 FIG 7 VOL I.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO COMPT FOUND CRACK 1 INCH LONG ON BEAM AT STA 6-70 STRINGER 42 RT SIDE. CUTTED DAMAGE AND INSTALL NEW SPLICE REPAIR IAW SRM 53-00-01 FIG 7 VOL I.