What was found
E & E BAY CORROSION ON FRAME SPLICE ANGLE AFT SIDE BS 460 STR 26L. REMOVED CORROSION ON FRAME SPLICE FOUND TO BE OUT OF LIMITS. FABRICATED NEW SPLICE ANGLE & INSTALLED ALL WORK DONE IAW SRM 53-10-1, 51-40-04, 51-30-2.