What was found
CORROSION AFT CARGO BAY FLOORBEAM LWR CHORD BS 1110 RBL 4 - 24 WL 200. CUT OUT DAMAGE ON LWR FLANGE OF BS 1110 FLOORBEAM RBL 2-RBL 26. FABRICATED AND INSTALLED REPAIR IAW FEDEX SR DRAWING SR 27-53-034E.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION AFT CARGO BAY FLOORBEAM LWR CHORD BS 1110 RBL 4 - 24 WL 200. CUT OUT DAMAGE ON LWR FLANGE OF BS 1110 FLOORBEAM RBL 2-RBL 26. FABRICATED AND INSTALLED REPAIR IAW FEDEX SR DRAWING SR 27-53-034E.