What was found
SLAT DISAGREE AFTER T/O PRIOR TO SLAT RETRACT. NO ROLL MOVEMENT. INDICATION STOPPED AT SLAT RETRACTION ON ARRIVAL SFS SLAT DISAGREE AGAIN. FOLLOWED CHECK LIST. NO SLAT LANDING WAS NORMAL. FOUND DAMAGED L/E STRUCTURE WHERE PULLY FOR NR 1 SLAT EXTEND CABLE IS MOUNTED. REF IPC 27-81 -35-01 PULLY MOUNTED NR 2 SLAT TRACK OUTBOARD WALL CAME OFF WITH PULLY. ABOUT 18" BY 18" OF PART OF WALL CAME WITH PULLY. REPAIR C/O ON LHW NR 2 SLAT TRACK O/B WEB AND SUPPORT AS PER FEDEX EA 1-5740-90695. (TITLE: WINGS-LEADING EDGE SLATS - LT NR 2 SLAT TRACK WEB AND SUPPORT REPAIR AT STATION XIS, = 211.719) SLAT OPS TEST AND ADJ AS PER MM 27-80-00 AND MM 27-80-20 AND FOUND SATISFACTORY.