What was found
RT MLG W/W ON STRUCTURE SLANT PANEL AT STA 1381 X-115 ON TEE FOUND SEVERE CORROSION WITH EXFOLIATION. REM SLANT PNL IAW MM20-50-02. AFTER REM SLANT PNL FOUND SEAL BROKEN AND QTY17 P/N AEA0476-505 CLAMP QTY4 P/N AEA0476-509, QTY3 P/N AEA0476-507, QTY1 P/N AEA0481-2 CLAMP WORN. REMOVED CORROSION IAW SRM 51-21-01PAR34 VOL1 ORIG MAT THK IS .260" IAW SRM 53-40-00 PAGE 55. MAT REM .088" REMAIN THK .172", MAT REM 33.8 PERCENT IS WITHIN LIMITS IAW SRM53-40-00 VOL1 FIG 11 SHT 1 IAW SRM 51-21-01 VOL2 PAR 22. PROTECTED AREA IAW RM53-40-00 VOL1 FIG11. INSTALLED SLANT PNL EXCEPT 3EA CLAMP IAW DWG AEA0441. INSTALL SLANT PANEL, FOUND QTY 1 P/N AEA0481-2 AND QTY2 P/N AEA0476-509 CLAMP WORN. REPLACED CLAMPS IAW DWG A