What was found
TURNING FINAL AT 3000' SELECTED SLATS EXTEND. NO SLAT EXTENSION NOTED AND ECAM INDICATED SLATS FAULT LIGHT. CYCLED HANDLE FOUR TIMES NO IMPROVEMENT. EMERGENCY DECLARED, LANDED WITH NO SLATS FLAPS 40 APPROACH, FOLLOWING RED TABS. AFTER TOUCHDOWN HANDLE WAS RECYCLED AND SLATS EXTENDED NORMALLY CHECKED SFCC AND FOUND SLAT JAM ON BOTH SFCC'S, RESET SFCC'S AND OPERATED SLATS NUMEROUS TIMES AND NO FAULTS. CHECKED SYSTEM TORQUE LIMITERS AND SCREW JACK LOCK, OUT INDICATORS AND NONE WERE TRIPPED, REF M/M 27-84-00-5 AND 27-84-00-0. NO HISTORY NINTY DAYS. A/C OK FOR SERVICE.