What was found
FOUND BS 1148 BETWEEN STRS 30 AND 29 RT SHEAR TIE IS CORRODED. REMOVED SHEAR TIE BS 1148 STR 29 & 30 R/H PER SRM 51-30-2. BLENDED CORROSION 3 X 3 .030. ORIG THICKNESS .063. FOUND TO BE OUT OF LIMITS. FABRICATED NEW SHEAR TIE USING 7075T6 .063 LOT #500810 PER SRM 51-20-1 ALODINE, PRIME & PAINTED PER 51-10-2. INSTALLED NEW SHEAR TIE PER SRM 51-30-2 BS 1148 STR 29 & 30.