What was found
AFTER T/O, NR 2 HYD LT EDP OVERPRESS, APPROX 4KPSI, PER QRH SHUT OFF THAT PUMP NOTICED NR 2 HYD TEMP WAS HI 70 DEG AND RISING FOLLOWED QRH NO HELP, RECEIVED LT TEMP HI ON NR 2 SYS. FOLLOWED QRH, NO HELP. TEMP KEPT RISING ON NR 2 SYS AT 120 DEG, SHUTDOWN NR 2 ENG. NR 2 ENG HYD PRESS HIGH DURING OP'S. FOUND NR 2 PRESS IND OUT OF TOL. R/R IND NR 2 LT HYD EDP NOT FULLY DEPRESS WHEN SEL'D OFF. R/R`D PUMP FLUID INSP IAW 29-11-01 NO DUCT DMG AND FILTER DELTA P POPPED. ENG RUN, FOUND NR 2 RT EDP NOT CLOSING DURING AUTO SELECTION W/THE LT PUMP FULLY PRESS. R&R R2-5415 AND TESTED PER TAFI, NO HELP. R&R NR 2 LT PRESS SW IAW 29-31-02, NO HELP, LK CKS OK. R/R`D NR 2 RT EDP DEPRESS SOL. R&R TEMP SENSOR CKS OK.