What was found
MAIN DECK FLOOR SUPPORT OB FLG LWR SURFACE IS CORRODED AT NUT CLIPS BS 330-340, RBL 41, WL 208. REMOVED SUPPORT BRACKET REF SRM 51-30-2 PG 2. DRILLED UP NEW FLOOR SUPPORT AND INSTALLED REF SRM 51-30-2 PG 5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK FLOOR SUPPORT OB FLG LWR SURFACE IS CORRODED AT NUT CLIPS BS 330-340, RBL 41, WL 208. REMOVED SUPPORT BRACKET REF SRM 51-30-2 PG 2. DRILLED UP NEW FLOOR SUPPORT AND INSTALLED REF SRM 51-30-2 PG 5.