As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
OTBD STUB WEB LOCATED AT STA 608, STR 2L AND DOOR SILL CHANNEL FOR MAIN CARGO DOOR, HAS FASTENER HOLE WITH NO EDGE DISTANCE. FABRICATED NEW STUB WEB REF DRAWING 53FX656 (REV B). THE PART IS TO BE INSTALLED ON SNRM N00492. CLASSIFIED AS A MAJOR REPAIR. REF HAYES INTERNATIONAL CORP DRAWING 53FX656 REV B.