What was found
MAIN DECK FLOORBEAM UPPER CHORD AND INTERCOSTAL ATTACHMENT HAS DOUBLE DRILLED/MISREPAIRED FASTENER HOLES AT BS 400, RBL 12, WL 208. REMOVED DAMAGE ON UPPER CHORD, REPAIRED AREA REF SRM 53-10-08 FIG 3, TABLE I. REMOVED AND REPLACED INTERCOSTAL AT 400-420, REF BOEING DRWG 65-6495. TREATED, PRIMED REF SRM 51-10-02 PG 1-2. CLASSIFIED AS MAJOR REPAIR.