AFT PIT STR 29L CORRODED STA 999 OUTBD SIDE. REMOVED CORROSION, CHECKED MATERIAL LOSS, ORIG MATERIAL = .156". REMOVED .036", ROTO PEENED, TREATED, PRIMED, PAINTED. INSTALLED FASTENERS (2EA) REF AAR EA NR I070060.