What was found
STRINGER CLIP HAS BEEN GROUND AT THE RADIUS CUT OUT BS 440 STR 3L REMOVED STR CLIP STA 440 STR 3L. RECEIVED CLEARANCE AND INSTALLED STR CLIP REF SRM 51-30-2 PG 1. CLASSIFIED AS MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STRINGER CLIP HAS BEEN GROUND AT THE RADIUS CUT OUT BS 440 STR 3L REMOVED STR CLIP STA 440 STR 3L. RECEIVED CLEARANCE AND INSTALLED STR CLIP REF SRM 51-30-2 PG 1. CLASSIFIED AS MAJOR REPAIR.