As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LWR AFT CARGO COMPT NR 4 FLOOR PANEL HAS SEVERAL DEEP GOUGES AND IS CRACKED THROUGH AT BS 1035 BL ''0'' CUT SHEETMATAL TO FORM OF OLD FLOOR PNL. JOGGLED EDGED, TRANSFERED FASTENER HOLES FOR PANEL, PRIMED BACK (UNDERSIDE) OF PNL. INSTALLED FASTENERS SECURING FLOOR PNL.