What was found
FOUND SEVERAL WIRES AND MOD BLOCKS BURNED AT S3-438 IN CENTER ACCESSORY LT SIDE JUST AFT OF EPC BAY NR 1 AT STA 1136 JUST BELOW FLOOR PANEL. INSPECTED AND REPAIRED DAMAGED WIRES AND MOD BLOCKS PER EA 1-2821-109931 "FUEL SYSTEM REPAIR/INSPECT DAMAGED WIRES". PERFORMED OPS CHECKS ON AFFECTED CIRCUITS PER W/D 23-41-03, 26- 23-01, 28-22-05, 32-44-01, 32-48-02, AND 36-15-01. ALL CHECKS NORMAL.