Service difficulty report · Control Unit · Doug MD11

Difficulty date
May 25, 2007
Submitted
May 31, 2007
Operation
Air carrier
Aircraft
N605FE
Make and model
Doug MD11
Aircraft serial
48514
Aircraft time
51,108 hours, 11,458 cycles
Part
Control Unit
Part number
750866D
Part serial
0126
Condition
Failed
Location
Emergency Power
Part time
151 hours, 34 cycles
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
C

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AT APPROX 00:00Z GOT A MASTER WARNING LT W/A LEVEL 1 EMERGENCY POWER ON ALERT. COMPLIED W/QRH. SELECTED EMERGENCY POWER SWITCH TO OFF. GOT LVL 1 L EMERGENCY AC BUSS ALERT. SELECTED EMERGENCY POWER SWITCH BACK TO ARM , STILL HAD EMERGENCY POWER ON LEVEL ONE ALERT. CONSULTED W/GOC AND MOCC VIA SAT. BATTERY VOLT NOW DOWN TO 24V -51. WHEN VOLT DROPPED TO 22V (AMBER) DEPLOYED ADG IN ELEC BATTERY CHARGED UP TO 32V, ELECTED TO DIVERT SEA. ON NEXT POWER UP, EMERGENCY POWER TEST FAILED. REF WDM 24-61-11, REMOVED AND REPLACED LEFT EMERGENCY CONTROL RELAY (R2-17) PER SMP. REF AMM 24-24-00-5 AND EPCU R-T-S REF AMM 24-08-01-5, ALL TEST PASSED AND CHECKED NORMAL. DID NOT DUPLICATE FAULT, FINAL FIX REMOVED AND