What was found
CABIN FLOOR SUPPORT WEB AT STA 804 RBL 45 IS CRACKED OUT FASTENER HOLE. REMOVED, FABRICATED AND INSTALLED FLOOR SUPPORT WEB STA 804, RBL 5, SRM 51-30-2, DWG 65-16279.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN FLOOR SUPPORT WEB AT STA 804 RBL 45 IS CRACKED OUT FASTENER HOLE. REMOVED, FABRICATED AND INSTALLED FLOOR SUPPORT WEB STA 804, RBL 5, SRM 51-30-2, DWG 65-16279.