What was found
ON AGING AC INSPECTION FOUND EXISTING REPAIR DID NOT CONFORM TO CURRENT FED EX SR27-53-034 AT BS STA 720D, LBL27"-43" FLOORBEAM. REMOVED OLD REPAIR, FABRICATED 2 NEW ANGLES, HEAT TREATED, CAD PLATED, PRIMED AND PAINTED. INSTALLED 2 NEW ANGLES AND FILLERS AT STA 720D, LBL 27"- 43" REF SRM 51-30-2, MM 51-20-151-7, AND FED EX DWG SR27-53-034F REPAIR NR 1.