What was found
AFT PIT STR CLIP FLOOR SUPPORT ANGLE CORRODED STR 29L, STA 970 REMOVED FLOOR SUPPORT, ORDERED NEW FLOOR SUPPORT, FABRICATED SHIM AND DRILLED UP NEW FLOOR SUPPORT. INSTALLED FLOOR SUPPORT AND SHIM REF SRM 51-30-2 PG 3, 5-7, SRM 51-10-2 PG 1, SRM 51-20-1 FIG 10.