What was found
CABIN FLOORBEAM AT BS 480 HAS SCRATCHES ON UPPER SURFACE OF UPPER TEE BETWEEN RBL 27 AND RBL 40 BLENDED DAMAGED AREA, NDT FOR MATERIAL LOSS ORIGINAL .130 REMOVAL .008, SELF CONTAINED SHOT PEEN AREA, APPLIED ALODINE AND PRIMED. APPLIED CORROSION INHIBITING COMPOUND, REF SRM 51-10-1, 51-20-5, MM 51-20-151, SOPM 20-10-3, EA NR 7-5310-113038. CLASSIFIED MINOR REPAIR.