What was found
CABIN BS 500 FLOORBEAM UPPER CHORD HAS SCRATCHES ON UPPER SURFACE BETWEEN BL 0 AND RBL 25 BLENDED AREA, VERIFIED MATERIAL LOSS, AND NO CRACK BY NDT, FLAP PEENED REF EA 7-5310-113039, TREATED AND PRIMED AREA. APPLIED CORROSION RESISTANT COMPOUND THIS IS CLASSIFIED AS A MINOR REPAIR.