What was found
AFT LOWER PIT STATION 1148 BILGE AREA, SHEAR TIE FRAME CORRODED, BETWEEN STR 30 AND STR 29L REMOVED CORROSION REF SRM 51-10-01. FOUND TO BE OUT OF LIMITS, ORIGINAL THICKNESS .066" REMAINING THICKNESS .043". REMOVED .023". REMOVED DAMAGE, FAB NEW FRAME REPAIR. INSTALLED NEW SHEAR TIE. REF SRM 53-10-4 FIG 11.