What was found
MAIN DECK 1L ENTRY DOOR SN 24, BOTTOM CROSS BEAM WEB IS CRACKED AT AFT STOP FITTING. REMOVED STOP FITTING, REMOVED DAMAGE, REPAIRED WEB. INSTALLED DOUBLER AND REINSTALLED STOP FITTING REF SRM 51-40-2 AND FED EX DWG SR27-52-015, THIS IS CLASSIFIED AS A MAJOR REPAIR.