What was found
AFT UPPER MAIN DECK, CORROSION ON UPPER SHEAR DECK, UNDER FLOORBOARDS, STA 1166 PLUS 8", RBL 17" TO RBL 36" (BETTER VIEW FROM LWR AFT PIT) REMOVED SEAT TRACK AT STA 1128 - 1178, RBL 25 AND 45. REMOVED ATTACHING STRUCTURE FOR SHEAR WEB REMOVAL. REMOVED SHEAR WEB. DRILLED UP SHEAR WEB. INSTALLED REMOVED STRUCTURE, SEAT TRACK, RBL 25-45 AND SHEAR WEB REF. 51-30-2, THIS IS CLASSIFIED AS A MINOR REPAIR.