What was found
AFT UPPER MAIN DECK, CORROSION ON UPPER SURFACE OF UPPER T- CAP ON FLOOR BEAM, STA 950, LBL 10.5 AND LBL 21". REMOVED CORROSION FROM SURFACE ON UPPER T-CAP REF SRM 51-10-01. REMOVED SEAT TRACK SRM 51-30-2. REMOVED WEB SUPPORT AND BRACKET AT 950. REMOVED TWO STRAPS BS 950 UNDER T- CAP, LBL 22-63. FAB REPAIR ANGLE, FAB UPPER T-CHORD, HEAT TREATED AND PRIMED, INSTALLED UPPER T-CHORD, BS 950, RBL 13 TO LBL 62. WORK ACCOMPLISHED ON EA NR 7-5310-113054. THIS IS CLASSIFIED AS A MAJOR REPAIR.