As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
UPPER MAIN DECK FLOOR STRUCTURE, UPPER BEAM CAP HAS MULTIPLE DRILL HOLES UNDER REMOVED SEAT TRACK STA 1166, RBL 25. INSTALLED TWO FREEZE PLUGS IN 1166 FLOORBEAM. PLUG TWO HOLES IN 1166 FLOORBEAM. DRILLED TWO HOLES IN 1166 FLOORBEAM. DRILLED TWO TO BLUE PRINT SIZE IN FREEZE PLUG. IN REF TO EA 7-5310-113070. THIS IS CLASSIFIED AS A MINOR REPAIR.